18 Years Factory Oil Fired Combi Boiler - Single Drum Steam Boiler – Double Rings
18 Years Factory Oil Fired Combi Boiler - Single Drum Steam Boiler – Double Rings Detail:
Introduction :
Single Drum Chain Grate Coal fired boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover.
The hopper of fuel drops to grate bar, then enter furnace for burning, by the ashes room above the back arch, the flame gets through the first backhaul fire tube to front smokebox, then turn back from front smokebox to the second flue for economizer and dust collector, at last, released into the atmosphere by the draft fan through chimney.
Feature:
1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.
Parameter :
DZG(L)Horizontal Type Coal-Burning Steam Boiler
Main Technology Parameter List
Model | DZG1-0.7-A II DZG1-1.0-A II DZG1-1.25-A II |
DZG2-1.0-A II DZG2-1.25-A II DZG2-1.57-AII |
DZG4-1.25-A II DZG4-1.57-A II |
DZL1-0.7-A II DZL1-1.0- A II DZL1-1.25- A II DZL1-1.57- A II DZL1-2.45- A II |
||
Rated Capacity T/h | 1 | 2 | 4 | 1 | ||
Rated Working Pressure Mpa | 0.7/1.0/1.25 | 1.0/1.25/1.57 | 1.25/1.57 | 0.7/1.0/1.25/1.57/2.45 | ||
Rated Steam Temp. ℃ | 170/183/194 | 183/194/204 | 194/204 | 170/183/194/204/226 | ||
Feed Water Temp. ℃ | 20 | 20 | 20 | 20 | ||
Fuel Consumption Kg/H | 170 | 330 | 600 | 170 | ||
Thermal Efficiency % | 77 | 77 | 78 | 78 | ||
Heating Surface m² | Boiler Body | 32.4 | 33.85 | 75.75 | 32.4 | |
Economizer | 12.51 | 24.64 | 38.5 | 12.51 | ||
Grate area m² | 1.37 | 2.3 | 2.05 | |||
Designed Fuel Type | Bituminous Coal | Bituminous Coal | Bituminous Coal | Bituminous Coal | ||
Max. Transport Weight T | 10.6 | 19.6 | 26.5 | 13.3 | ||
Max. Transport Dimension m | 4.75×2.1×2.6 | 5.7×3.4×4.6 | 5.49×2.6×3.5 | 5.65×2.1×2.6 | ||
Boiler Auxiliary Equipment Model and Specification | ||||||
Air Blower | Model | T4-72-11;3.2A;Right225° | T4-72-11;3.2A;Righ 315° | T4-72-11;4A; Right 315° | T4-72-11;3.2A; Right 225° | |
Motor Power | N=1.5 Kw | N=3 Kw | N=5.5 Kw | N=1.5 Kw | ||
Draft Fan | Model | YX9-35-11;5C ; Right 0° | Y-9-26;6.3C ; Right 0° | Y-9-26;9D;Right 0° | YX 9-35-11;5C; Right 0° | |
Motor Power | N=5.5 Kw | N=11 Kw | N=22 Kw | N=5.5 Kw | ||
Gear Box | Model | GL-5P | ||||
Motor Power | N=0.55 Kw | |||||
Feed Water Pump | Model | 1.5WCT-120 | 1½ GC5x7 | 1½ GC5x7 | 1.5WCT-120 | |
Motor Power | N=2.2 Kw | N=7.5 Kw | N=7.5 Kw | N=2.2 Kw | ||
Dust Remover | Model | XD-1 | XD-2 | XD-4 | XD-1 |
Model | DZL2-1.0-AII DZL2-1.25-AII DZL2-1.57-AII DZL2-2.45-AII |
DZL4-1.25-AII DZL4-1.57-AII DZL4-2.45-AII |
DZL6-1.25-AII DZL6-1.57-AII DZL6-2.45-AII |
DZL8-1.57-AII | DZL10-1.25-AII DZL10-1.57-AII DZL10-2.45-AII |
|||
Rated Capacity T/h | 2 | 4 | 6 | 8 | 10 | |||
Rated Working Pressure Mpa | 1.0/1.25/1.57/2.45 | 1.25/1.57/2.45 | 1.25/1.57/2.45 | 1.57 | 1.25/1.57/2.45 | |||
Rated Steam Temp. ℃ | 183/194/204/226 | 194/204/226 | 194/204/226 | 203.04 | 194/204/226 | |||
Feed Water Temp. ℃ | 20 | 20 | 20/60 | 20 | 20/60 | |||
Fuel Consumption Kg/H | ~310 | ~590 | ~900 | ~1200 | ~1440 | |||
Thermal Efficiency % | 78 | 80 | 77.44 | 78 | 80.6 | |||
Heating Surface m² | Boiler Body | 33.85 | 75.75 | 142 | 205 | 347 | ||
Economizer | 24.64 | 38.5 | 87.2 | 139.52 | ||||
Grate area m² | 3.5 | 4.66 | 7.4 | 8.4 | 10.98 | |||
Designed Fuel Type | Bituminous Coal | Bituminous Coal | Bituminous Coal | Bituminous Coal | ||||
Max.Transport Weight Ton | 21 | 26.5 | 38 | 33 | 28/29 | |||
Max. Transport Dimension m | 5.9×2.2×3.3 | 6.5×2.6×3.524 | 7.4×3.2×4.2 | 8.1×3.2×4.2 | 7.6×3.2×3.5 | |||
Boiler Auxiliary Equipment Model and Specification | ||||||||
Air Blower | Model | T4-72-11;3.2A;Right315° | T4-72-11;4A;Righ 315° | T4-72-11;5A; Right 225° | GG8-Na;7.1A; Right 225° | 10TG811DRight 225° | ||
Motor Power | N=3 Kw | N=5.5 Kw | N=11 Kw | N=11 Kw | N=15 Kw | |||
Draft Fan | Model | Y9-26;6.3C; Right 0° | Y-9-26;9D; Right 0° | Y-8-39;9D;Right 0° | GY8-1;Na9.5D;Right 0° | 10JY;9.5D; Right 0° | ||
Motor Power | N=11 Kw | N=22 Kw | N=30Kw | N=37Kw | N=45 Kw | |||
Gear Box | Model | GL-5P | GL-5P | GL-10P | GL-16P | |||
Motor Power | N=0.55 Kw | N=0.55 Kw | N=1.1 Kw | N=1.1 Kw | ||||
Feed Water Pump | Model | 1½ GC 5×7 | 1½ GC 5×7 | DG 6-25×7 | 2GC-5xT | 1½ GC 6×6 | ||
Motor Power | N=7.5 Kw | N=7.5 Kw | N=7.5 Kw | N=22 Kw | N=2.2 Kw | |||
Dust Remover | Model | XD-2 | XD-4 | XD-6 | XD-8 | XD-10 |
Product detail pictures:

Related Product Guide:
Boiler Structure
Each individual member from our large performance revenue crew values customers' needs and company communication for 18 Years Factory Oil Fired Combi Boiler - Single Drum Steam Boiler – Double Rings , The product will supply to all over the world, such as: Mozambique, Frankfurt, Libya, Each customer's satisfactory is our goal. We are looking for long-term cooperation with each customer. To meet this, we keep up our quality and provide extraordinary customer service. Welcome to our company, we are expecting to cooperate with you.

The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.