Best Price for Heating Water Boiler - Boiler Sample Cooling Collection – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

We continuously execute our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management advertising and marketing gain, Credit history attracting buyers for vertical thermal oil boiler for sale, boiler accessory ladderChinese boiler ladder, bagasse steam boiler, We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.
Best Price for Heating Water Boiler - Boiler Sample Cooling Collection – Double Rings Detail:

Used in Boiler

Sampling Cooler 
This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project.
An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant.
The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils;
It can effectively improve the accuracy of water quality analysis, and at the same time the connecting point between the equipment is simple.
 
Structure
Connected with flange cover the top of the cooling water tank is equipped with coil pipe mouth of the flange cover with holes, in the middle of the cooling coil set in cooling water in the box, the outlet and inlet end of the cooling coil respectively through Kong Yanshen to cooling water tank, among them, the entry of the cooling coil and connected to the boiler, the export of cooling coil, directly above the bus slot of the water in the cooling coil by cooling coil exports into confluence worse, bus slot connected at the bottom of the drain;
The bottom of the cooling water tank is provided with a water inlet, the outlet of the water inlet pipe is connected with the water inlet of the cooling water tank;
The top of the cooling water tank is also provided with an outlet, and the inlet of the outlet pipe is connected with the outlet of the cooling water tank .
 
Principle
Sampling cooler used for boiler room or soda assay sample cooling power station, the water in the boiler and heating system mostly higher temperature, and high temperature is not convenient to sampling, also not easy to determine, in the sample should be cool, so let’s introduce the sample of sampling point sampling cooler for cooling, general requirements to ensure traffic in the 500-700 ml/min, the sample can take a 30 to 40 degrees cold, satisfy the People’s Republic of China power industry DL/T 457-91 standard.
 
Characteristics 
The sampling cooler is suitable for sampling medium such as liquid and gas with high temperature. It has the advantages of compact structure, high heat transfer efficiency, convenient cleaning and long service life.
 
Specifications
1: The sampler tube is stainless steel and the housing is carbon steel.
2. Generally, the sampling cooling pipe can be welded and flange with diameter of 10, 12, 14, 16 and 18mm (or optionally specified by the user). The cooling water interface is DN25 with external thread.
3: The general types are qYl-159/0.32, QYl-219/0.40 and QYl-273/0.54.
4: Whether to combine (that is, whether to support, water tank, valve, etc..
 
Sampling procedure
1.Boiler water sampling
The boiler water sample is generally taken out of the continuous drain pipe of the drum and sent to the cooler.
The sampling point should be as close as possible to the outlet of the drain line drain drum and as far as possible before the first drain valve behind the drain drum.2.Sampling of feed water
The sampling point of the water supply is generally set after the feed pump, and a small pipe should be connected to the vertical pipe line of the water supply pipe on the high-pressure feed pipe before the economizer, from which the sample of the water supply is led to the sampling cooler.
The sampling tube of the feed water should be located at a place where the feed water can be mixed after dosing.
3.Sampling of condensed water
The condensate water sampling point is generally located in the condensate water pipe at the outlet of the condensate pump, should not be installed in the condensate pump entrance, because the pressure of the condensate pump entrance is lower than atmospheric pressure.
4.Hydrophobic sampling
The drainage is generally sampled in the drainage tank.
The sampling point is usually located about 300mm away from the bottom of the drain tank.
Steam samples are condensed into water through the sampling cooler.
The steam flow rate in the steam sampler is generally 20-30kg/h.
The requirements for the sample lead – out duct and cooler are the same as for water sampling.by metal corrosion products in the tubes during sampling.
 
Attention
Stainless steel tubes shall be used for sampling. Carbon steel tubes or brass tubes shall not be used to avoid contamination of the samples by metal corrosion products in the tubes during sampling.
sampling


Product detail pictures:

Best Price for Heating Water Boiler - Boiler Sample Cooling Collection – Double Rings detail pictures

Best Price for Heating Water Boiler - Boiler Sample Cooling Collection – Double Rings detail pictures


Related Product Guide:
Boiler Structure

We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for Best Price for Heating Water Boiler - Boiler Sample Cooling Collection – Double Rings , The product will supply to all over the world, such as: Gabon, Muscat, Detroit, Abiding by our motto of "Hold well the quality and services, Customers Satisfaction", So we give our clients with high quality products and solutions and excellent service. Be sure to feel free to contact us for further information.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Tony from Croatia - 2017.02.18 15:54
    We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Pandora from Slovenia - 2018.02.04 14:13
    Write your message here and send it to us

    Related products

    • Biomass Wood Fired Steam Boiler - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      Biomass Wood Fired Steam Boiler - Coal Boiler ...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

    • China Cheap price Biomass Boiler - Vertical Gas Oil Boiler – Double Rings

      China Cheap price Biomass Boiler - Vertical Ga...

      Introduction : 1. Compact structure, small installation area, easy to install. 2. Good heating surface , low exhaust gas temperature 3. The world famous original burner, automatic and high efficient combustion, high combustion efficiency 4. Microcomputer automatic controller, overpressure protection and ultra-low water level automatic protection and automatic feed water . 5. Super thickness insulating layer design, good insulation effect, boiler surface temperature low, low losing he...

    • Electric Boiler China - Gas oil Boiler Economizer – Double Rings

      Electric Boiler China - Gas oil Boiler Economi...

      More photo Boiler economizers are heat exchange devices with finned tubes that heat a liquid, sometimes water, up to however sometimes doesn’t exceed the boiling purpose of liquid. We can manufacture three types of boiler economizer, bare tube economizer, H finned tube economizer and spiral finned tube economizer. H-finned tube economizer is high efficient heat exchanger economizer which is consisted of H-finned tubes.

    • Original Factory Biomass Fired Boiler - Boiler Ladder and Stair – Double Rings

      Original Factory Biomass Fired Boiler - Boiler...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • Bottom price Industrial Hot Water Boiler - Single Drum Hot Water Boiler – Double Rings

      Bottom price Industrial Hot Water Boiler - Sin...

      Parameter : DZG(L)Bearing Pressure Hot water boiler Main Technology Parameter List Model DZG0.7-0.7/95/70 DZL0.7-0.7/95/70  DZG1.4-0.7/95/70 DZL1.4-0.7/95/70 DZL1.4-1.0/115/70 DZL28-1.0/115/70 DZL2.8-1.25/130/70 DZL4.2-1.0/115/70 DZL4.2-1.25/130/70 Rated Capacity T/h 0.7 1.4 2.8 4.2 Rated Working Pressure Mpa 0.7 0.7/1.0 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 95 95/115 115/130 115/130 Feed Water Temp. ℃ 70 70 70 70 Fuel Consumption  Kg/H ~150 ~310 ~590 ~900 Thermal Efficiency ...

    • New Arrival China Hot Water Boiler - heat recovery boiler – Double Rings

      New Arrival China Hot Water Boiler - heat reco...

      Introduction: Main Performance Parameter List Steam Pressure 1.0~2.5 Mpa Inlet Temperature 250℃ Saturation Temperature 179℃ Heating Water:Inlet Temperature 90℃; Outlet Temperature 140℃