China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

Sticking to the belief of "Creating products of high quality and making friends with people from all over the world", we always put the interest of customers in the first place for Fire Tube Boilers, oil boiler economizer, Industrial Hot Water Boiler, Your inquiry might be extremely welcomed plus a win-win prosperous development are what we've been expecting.
China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings Detail:

Introduction :

SZS series boiler body is longitudinal 2-drum, D-type chamber combustion strueture. The furnace is on right side and the convection bank tube is on left side. The body is fixed on the body chassis by flexible supports in the middle and two ends of the lower drum,can secure to let the whole boiler body to expand sideways. Surround furnace there are narrow space membrane cooling tube wall. It is totally sealed and separated between the membrane wall on furnace left side and the convection bank tube. The rear part of convection tube bank is a tube-reducing staggered structure,
and the front part is aligned structure. The flue gas generated from furnace combustion flows from furnace rear outlet to the end of combustion chamber, convection tube bank area, amt then turns from the front-left of furnace to the spiral finned tube energy saver, and finally flows into ducting and through chimney emits to atmosphere.

Feature:

1. Due to combustion chamber applying whole membrane water cooling structure.and adopted micro–positive pressure combustion, there is no smoke leakage, and there is no pollution in operation environment;
2. There are explosion door and flame sensor in the boiler arrangement and so operation is safe and reliable;
3. At boiler rear, it adopts the spiral finned tube type energy saver that reduces flue gas emission temperature and therefore raises thermal efficiency. The design efficiency is above 92%;
4.The boiler is horizontal arrangement in compact structure with small floor space area;
5.The manholes are arranged at the two ends of upper and lower drums, and check door is set a rear part of boiler. These openings make users easy for entering inside doing maintenance and cleaning work;
6. The boiler is wholly assembled for delivery, easy for transportation and shortened for installation period;
7.The boiler achieves fully automatic control. It has the functions of automatic running and protection with easy operation.


Product detail pictures:

China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings detail pictures

China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings detail pictures

China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for China Biomass Boiler Pdf - SZS Gas Oil PLG Boiler – Double Rings , The product will supply to all over the world, such as: Portugal, Accra, Slovenia, We warmly welcome your patronage and will serve our clients both at home and abroad with products of superior quality and excellent service geared to the trend of further development as always. We believe you will benefit from our professionalism soon.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Amber from Swedish - 2018.10.31 10:02
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Alex from Madrid - 2018.06.09 12:42
    Write your message here and send it to us

    Related products

    • Trending Products Boiler System - heat recovery boiler – Double Rings

      Trending Products Boiler System - heat recover...

      Introduction: Main Performance Parameter List Steam Pressure 1.0~2.5 Mpa Inlet Temperature 250℃ Saturation Temperature 179℃ Heating Water:Inlet Temperature 90℃; Outlet Temperature 140℃

    • Excellent quality Industrial Boiler Ltd - Boiler Installation Material – Double Rings

      Excellent quality Industrial Boiler Ltd - Boil...

      Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...

    • Good User Reputation for Outdoor Coal Boiler - Well-designed Biomass Pellet Boiler - Coal Boiler Biomass Boiler Reducer – Double Rings – Double Rings

      Good User Reputation for Outdoor Coal Boiler -...

      Reducer used in DR Boiler • The main parts adopt high quality carbon structural refined steel.With high strength, high transmission efficiency and reliable operation, long service life, etc. • Respectively using multilevel, stepless frequency conversion speed regulating mode. User can reasonably match speed reducer according to the different operation condition of boiler.With the features of easy operation, energy saving, etc • With characteristics of large transmission torque and speed...

    • Best Oil Fired Boiler To Buy - Pellets Shells Husk Biomass Boiler – Double Rings

      Best Oil Fired Boiler To Buy - Pellets Shells ...

      Parameter : DZG(L)Horizontal Type Biomass-Burning Steam Boiler Main Technology Parameter List Model DZG2-1.0-S DZL2-1.25-S DZL2-1.57-S DZL2-2.45-S   DZG4-1.25-S DZL4-1.25-S DZL4-1.57-S DZL4-2.45-S DZL6-1.25-S DZL6-1.57-S DZL6-2.45-S  DZL8-1.25-S DZL8-1.57-S DZL8-2.45-S DZL10-1.25-S DZL10-1.57-S DZL10-2.45-S Rated Capacity T/h 2 4 6 8 10 Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 Rated Steam Temp. ℃ 183/194/204/226 194/2...

    • Renewable Design for Hot Water Boilers - Pellets Shells Husk Biomass Boiler – Double Rings

      Renewable Design for Hot Water Boilers - Pelle...

      Parameter : DZG(L)Horizontal Type Biomass-Burning Steam Boiler Main Technology Parameter List Model DZG2-1.0-S DZL2-1.25-S DZL2-1.57-S DZL2-2.45-S   DZG4-1.25-S DZL4-1.25-S DZL4-1.57-S DZL4-2.45-S DZL6-1.25-S DZL6-1.57-S DZL6-2.45-S  DZL8-1.25-S DZL8-1.57-S DZL8-2.45-S DZL10-1.25-S DZL10-1.57-S DZL10-2.45-S Rated Capacity T/h 2 4 6 8 10 Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 Rated Steam Temp. ℃ 183/194/204/226 194/2...

    • OEM/ODM China New Boiler - Single Drum Hot Water Boiler – Double Rings

      OEM/ODM China New Boiler - Single Drum Hot Wat...

      Parameter : DZG(L)Bearing Pressure Hot water boiler Main Technology Parameter List Model DZG0.7-0.7/95/70 DZL0.7-0.7/95/70  DZG1.4-0.7/95/70 DZL1.4-0.7/95/70 DZL1.4-1.0/115/70 DZL28-1.0/115/70 DZL2.8-1.25/130/70 DZL4.2-1.0/115/70 DZL4.2-1.25/130/70 Rated Capacity T/h 0.7 1.4 2.8 4.2 Rated Working Pressure Mpa 0.7 0.7/1.0 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 95 95/115 115/130 115/130 Feed Water Temp. ℃ 70 70 70 70 Fuel Consumption  Kg/H ~150 ~310 ~590 ~900 Thermal Efficiency ...