Our products and solutions are greatly recognized and trustworthy by customers and may fulfill constantly changing financial and social requires for vertical thermal oil boiler for sale, gas boiler economizer, Industrial Boiler Ltd, We welcome you to definitely inquire us by simply call or mail and hope to develop a prosperous and cooperative connection.
China Boiler Tube - AAC Autoclave and Boiler – Double Rings Detail:

Autoclave Characteristics

1 The autoclave is steel horizontal tube-type device, the autoclave lid is pressed by the whole block 16MnR steel, the flange of autoclave body and autoclave lid is used the 16Mn steel in the whole forging processing. The weld parts have been heat treatment and strict nondestructive testing in accordance with relevant standards.
2. Autoclave door is activity Open structure by hand-reducer. The clients can also choice the electric, pneumatic, hydraulic style to open and close.
Equipped with a perfect safety interlock protection device to maximum avoid mistake operation, and to ensure the safe operation of the autoclave and operator safety production.
The autoclave door has two types for the user to choose : 1. Side open 2. Up Open. Side open style adopts Rotating arm side open door structure, rotating flexible, low place operating , easy to operate . Up Open style adopts leveraged open door structure, the lower end of leverage connect with the autoclave door , the upper end equipped lift equipment, this type is portable to open, and small space in the autoclave side.
3. The autoclave door seal is imported rubber seals by professional manufacturers , simple installation, good sealing and long service life.
The autoclave body bearing has equipped the three style of fixed bearing, move bearing and end special bearing in different parts. It is best to be suitable for the thermal expansion and contraction of autoclave, to ensure the normal work of the autoclave and useful life.
4. The autoclave has a safety valve, pressure gauge, temperature measurement devices, inlet and exhaust valves, sealing ball valves, steam traps and other necessary valves and instrumentation, and equipped with decontamination tank for the user optional.
5. Besides the normal steam distribution pipes and guide rails, we specially set up the sealed steam protection cover and
Conventional steam distribution pipes and rails parts except the kettle, we more the sake of customers, set up a special sealed vapor scour protection cover and drain cover.
6. The autoclave design advanced and rigorous production, strictly follow the National Pressure Vessel Code.

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

China Boiler Tube - AAC Autoclave and Boiler – Double Rings detail pictures

China Boiler Tube - AAC Autoclave and Boiler – Double Rings detail pictures

China Boiler Tube - AAC Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our target is always to satisfy our customers by offering golden support, superior value and high quality for China Boiler Tube - AAC Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Japan, Mauritania, Gambia, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Tony from Namibia - 2018.06.28 19:27
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Jenny from Johannesburg - 2017.08.28 16:02
    Write your message here and send it to us

    Related products

    • Wholesale Price Industrial Boiler - Boiler Valve and Meter – Double Rings

      Wholesale Price Industrial Boiler - Boiler Val...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • Excellent quality Industrial Boiler Ltd - Boiler Installation Material – Double Rings

      Excellent quality Industrial Boiler Ltd - Boil...

      Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...

    • Fixed Competitive Price Electricity Boiler - Coal Boiler Biomass Boiler Water Flim Dust Cleaner – Double Rings

      Fixed Competitive Price Electricity Boiler - C...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • Low MOQ for Condensing Gas Boilers - Coal Boiler Biomass Boiler Slag Remover – Double Rings

      Low MOQ for Condensing Gas Boilers - Coal Boil...

      Slag Remover used in Coal Boiler Introduction The Slag Remover is a kind of boiler slag tapping equipment. The carbon slag produced after the coal is burned in the boiler is pushed to the slag storage pit by the grate, and is dragged out of the furnace by the slag machine to clear the slag accumulation.  Technology The high-temperature slag discharged from the furnace is first crushed into small pieces by a pair-roller slag breaker, which is convenient for cooling and transportation; th...

    • OEM/ODM China Hot Water Pipe - Boiler Water Pump – Double Rings

      OEM/ODM China Hot Water Pipe - Boiler Water Pu...

      Water Pump used in Boiler Components in contact with water—made of  SS304 or SS316 Head:  4~305m Flow rate:0.4~240m^3/h Phase: single phase or three phase Power: 220V/380V Connection: flange or threaded

    • China Fire Tube Boiler Manufacturer - Boiler Ladder and Stair – Double Rings

      China Fire Tube Boiler Manufacturer - Boiler L...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...