China Cfb Boiler Factories - Biomass Hot Water Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

With this motto in mind, we've got develop into amongst one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for boiler accessories, Electric Water Boilers, Pressure Vessel, We are always looking forward to forming successful business relationships with new clients around the world.
China Cfb Boiler Factories - Biomass Hot Water Boiler – Double Rings Detail:

Introduction :

Biomass boiler is horizontal three-back water fire pipe composite boiler. The fuel can be Biomass,coal,wood,rice husk,shells,pellets,bagasse,waste etc..

Display

PELLETS SHELLS HUSK BIOMASS BOILER

Feature:

1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.

xiangqingpic

Parameter :

DZG(L)Bearing Pressure Hot water boiler

Main Technology Parameter List

Model DZG0.7-0.7/95/70
DZL0.7-0.7/95/70
DZG1.4-0.7/95/70
DZL1.4-0.7/95/70
DZL1.4-1.0/115/70
DZL28-1.0/115/70
DZL2.8-1.25/130/70
DZL4.2-1.0/115/70
DZL4.2-1.25/130/70
Rated Capacity T/h 0.7 1.4 2.8 4.2
Rated Working Pressure Mpa 0.7 0.7/1.0 1.0/1.25 1.0/1.25
Rated Steam Temp. 95 95/115 115/130 115/130
Feed Water Temp. 70 70 70 70
Fuel Consumption  Kg/H ~150 ~310 ~590 ~900
Thermal Efficiency  % 75 78 79 77.44
Heating Surface Boiler Body  32.4 33.85 75.75 142
Economizer  24.64 38.5 87.2
Grate area   m² 1.4/2.05 2.3/3.5 4.66 7.4
Designed Fuel  Type Biomass Biomass Biomass Biomass
Max. Transport Weight  T ~16 ~21 ~26.5 ~30
Max. Transport Dimension  m 4.3×2.25×2.955.26×2.25×2.95 5.1×2.2×3.35.9×2.2×3.3 6.5×2.6×3.5 6.01×3.4×3.57.29×2.9×1.7

 

 

Model DZL7-1.0/115/70 DZL14-1.0/115/70 DZL29-1.25/130/70 DZL46-1.25/130/70 DZL58-1.25/130/70 DZL70-1.25/130/70
Rated Capacity T/h 7 14 29 46 58 70
Rated Working Pressure Mpa 1.0 1.0 1.25 1.25 1.25 1.25
Rated Steam Temp. 115 115 130 130 130 130
Feed Water Temp. 70 70 70 70 70 70
Heating AreaBoiler Body 228.6 434.7 Radiation:73.07Convection:903.01 Radiation:147.8Convection:1418.5 Radiation:147.8Convection:1418.5 Radiation:147.8Convection:1418.5
Grate area   m² 11.5 22.5 34.5 57.8 77 91
Fuel Consumption Kg/h ~1440 ~2700 ~6610 ~10500 ~12800 ~15300
Thermal Efficiency  % 80 80 82.5 82.05 83.03 83.28
Max. Transport Weight  Ton 35 28 19.68 28.796 31 31

Note: Parameter is just for reference, the exact parameter should follow the factory technical data.


Product detail pictures:


Related Product Guide:
Boiler Structure

With this motto in mind, we have turn out to be amongst probably the most technologically innovative, cost-efficient, and price-competitive manufacturers for China Cfb Boiler Factories - Biomass Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: Sheffield, Turkey, Ghana, Taking the core concept of "to be the Responsible". We'll redound up on society for high quality merchandise and good service. We will initiative to participate in international competition to be a first- class manufacturer of this product in the world.
The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
5 Stars By Linda from Netherlands - 2017.12.09 14:01
Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
5 Stars By Roxanne from Zurich - 2018.12.30 10:21
Write your message here and send it to us

Related products

  • Hot New Products Boiler Accessory - Coal Boiler Biomass Boiler F.D.Fan – Double Rings

    Hot New Products Boiler Accessory - Coal Boile...

    FD Fan used in Coal Boiler Industrial centrifugal blower fan is used for steam boilers, which has good quality and high efficiency. According to your requirements, we can provide technical solution and technical solution. Below industrial blower fan picture for your reference.

  • China New Product Electric Heating Boilers - SHL Bulk Industrial Boiler – Double Rings

    China New Product Electric Heating Boilers - S...

    Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

  • OEM Manufacturer Lpg Boiler - Double Drum Hot Water Boiler – Double Rings

    OEM Manufacturer Lpg Boiler - Double Drum Hot ...

    Parameter : SZL Bearing Pressure Hot water Boiler Main Technology Parameter List ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 115/130 115/130 115/130 Feed Water Temp. ℃ 70 70 70 Fuel Consumption  Kg/H ~580 ~900 ~1130 Thermal Efficiency  % 78 80 80 Heating Surface Boil...

  • Hot Selling for Oil Fired Boiler - LPG Pressure Tank – Double Rings

    Hot Selling for Oil Fired Boiler - LPG Pressur...

    Introduction: Pressure vessel equipment plays an important role in the petrochemical industry, the energy industry, scientific research and military sectors etc. Pressure vessel container body consist of cylinder, sealing head, flange, sealing elements, open pore and connected pipe, bearing. In addition, also equipped with safety devices, meter and safety internals for protection purpose . Pressure Vessel Main Performance Parameter List Steam Pressure1.0Mpa Inlet Temperature 250℃ S...

  • Professional China Water Tube Boiler - Boiler Water Treatment – Double Rings

    Professional China Water Tube Boiler - Boiler ...

    More photos 1. Quartz sand filter — mainly used for the removal of sediment from water. 2. Active Carbon filter– mainly used for chlorine removal and other organic gases and to clear up the taste of water . 3. Water Softener– exchange “ions” of calcium and magnesium with the most common and easiest method. 4. Precision filter– mainly used for removing microorganisms,chlorine,part of the heavy metal ions more precisely 5. High pressure pump– Provi...

  • China Wood Chip Biomass Boiler Supplier - heat recovery boiler – Double Rings

    China Wood Chip Biomass Boiler Supplier - heat...

    Introduction: Main Performance Parameter List Steam Pressure 1.0~2.5 Mpa Inlet Temperature 250℃ Saturation Temperature 179℃ Heating Water:Inlet Temperature 90℃; Outlet Temperature 140℃