China OEM Natural Gas Hot Water Boiler - SHX Circulating Fluidized Bed Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for Diesel Boiler, Hot Water Pipe, chinese hot oil boiler, With us your money in protected your business enterprise in secure . Hope we can be your trustworthy supplier in China . Searching forward for your cooperation .
China OEM Natural Gas Hot Water Boiler - SHX Circulating Fluidized Bed Boiler – Double Rings Detail:

Introduction:

As a new type of mature high-performance with low-pollution clean coal technology.
circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics.
1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfurization rate is economical.
2. Circulating fluidized bed boiler could adopt various coal types and has high combustion efficiency, which is especially suitable for low quality, low calorific value coal.
3.The ash of circulating fluidized bed boiler is of high activity, thus it is easy to realize comprehensive utilization without secondary pollution.
4.Circulating fluidized bed boiler could adjust its load in a wide range. Lowest load can be reduced to 30% Of full capacity.
Our recommendation—the of low magnification circulating fluidized bed boiler products have completely solved the problems like boiler abrasion, slagging and ash blocking of feed recycle device.original emission concentration of boiler and deslagging. Now the requirement on environmental protection is increasingly strict.As raw coal’s proportion of direct-fired is high. which makes the contradiction between coal and environmental protection more and more acute. Under such background, circulating fluidized bed boiler with the features of environmental protection and energy saving is your best choice.

Quality Control

1 Strength Calculation Report for Applied Materials after Inspection Machine inspected.
2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod;
3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler;
4 Hydraulic test report:ensure the standard working pressure and safety;
5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province
6 Manufacturer Produce Level  Grade-A.  Product Reach European Standard CE Marks.

Inspection Machinery for the Boiler in Workshop and Laboratory :

No. Name Model Qty
1 Digital Carbon & Sulfur Analysis Meter HV-4B 1set
2 High Speed Self-Ignition Furnace HB-2H 1set
3 Electric Scale JA1003 1set
4 Photometer 723 1set
5 Metallography Scale XJB-2A 1set
6 Hydraulic Multi-propose Test Machinery WE-100 1set
7 WE-600A 1set
8 Concussion Testing Machine JB-30 1set
9 Projective Meter JS 1set
10 X Ray Crack Detector XXH3005 1set
11 XXH2505 XXXXH23005 2sets
12 XY2515 2sets
13 Ultrasonic Crack Detector CTS-22 2sets

Product detail pictures:

China OEM Natural Gas Hot Water Boiler - SHX Circulating Fluidized Bed Boiler – Double Rings detail pictures

China OEM Natural Gas Hot Water Boiler - SHX Circulating Fluidized Bed Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our commission is to serve our buyers and purchasers with most effective good quality and aggressive portable digital goods for China OEM Natural Gas Hot Water Boiler - SHX Circulating Fluidized Bed Boiler – Double Rings , The product will supply to all over the world, such as: Florida, azerbaijan, Bangladesh, In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Colin Hazel from Armenia - 2018.09.21 11:44
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Pag from Czech Republic - 2018.06.19 10:42
    Write your message here and send it to us

    Related products

    • Hot-selling Industrial Electric Boiler - Oil Steam Boiler – Double Rings

      Hot-selling Industrial Electric Boiler - Oil S...

      Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

    • China Lpg Hot Water Boiler Supplier - Installation & Technology Service – Double Rings

      China Lpg Hot Water Boiler Supplier - Installa...

      Installation Procedure Step 1. Slag Extruder put into Foundation| Step 2. Lift Boiler Body to Foundation . Then install the Platform and Stair. Step 3.Connect Boiler,Economizer (Down Part) and Gas Flue. Step 4. Connect Economizer ( Up Parts) and Gas Flue. Step 5.Use asbest rope to Fix Economizer and Gas Flue. Keep no gas leak. Step 6. Lift Dust Cleaner to Foundation. Step 7.Connect and fix the Gas Flue between Dust Cleaner and Economizer . Step 8. Lift I.D Fan to Foundation Step...

    • Natural Gas Steam Boiler Factory - Boiler Electric Control – Double Rings

      Natural Gas Steam Boiler Factory - Boiler Elec...

      More Photos Electric Control Container Overview 2-4T 6T 10T 15T 20T 25T Sheet 1: 2t steam boiler electrical instrument control system configuration (common configuration 1.25Mpa) Features name Specification unit Qty Brand Electrical control           Induced draft fan control 11KW  Star Delta Start  set  1  Zhengtai Blower control  3KW  Direct start  set  1  Grate control  0.55KW  Direct start  set  1  Coal machine control 1.1KW  Direct start  set  1  Slag machine control ...

    • China Biomass Boiler Factories - Pellets Shells Husk Biomass Boiler – Double Rings

      China Biomass Boiler Factories - Pellets Shell...

      Parameter : DZG(L)Horizontal Type Biomass-Burning Steam Boiler Main Technology Parameter List Model DZG2-1.0-S DZL2-1.25-S DZL2-1.57-S DZL2-2.45-S   DZG4-1.25-S DZL4-1.25-S DZL4-1.57-S DZL4-2.45-S DZL6-1.25-S DZL6-1.57-S DZL6-2.45-S  DZL8-1.25-S DZL8-1.57-S DZL8-2.45-S DZL10-1.25-S DZL10-1.57-S DZL10-2.45-S Rated Capacity T/h 2 4 6 8 10 Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 Rated Steam Temp. ℃ 183/194/204/226 194/2...

    • Factory directly supply Wood Pellet Boiler - SHF Coal Water Slury Steam Boiler – Double Rings

      Factory directly supply Wood Pellet Boiler - S...

      Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

    • Natural Gas Steam Boiler Manufacturer - Installation & Technology Service – Double Rings

      Natural Gas Steam Boiler Manufacturer - Instal...

      Installation Procedure Step 1. Slag Extruder put into Foundation| Step 2. Lift Boiler Body to Foundation . Then install the Platform and Stair. Step 3.Connect Boiler,Economizer (Down Part) and Gas Flue. Step 4. Connect Economizer ( Up Parts) and Gas Flue. Step 5.Use asbest rope to Fix Economizer and Gas Flue. Keep no gas leak. Step 6. Lift Dust Cleaner to Foundation. Step 7.Connect and fix the Gas Flue between Dust Cleaner and Economizer . Step 8. Lift I.D Fan to Foundation Step...