Parameter :
DZG(L)Bearing Pressure Hot water boiler
Main Technology Parameter List
Model | DZG0.7-0.7/95/70 DZL0.7-0.7/95/70 |
DZG1.4-0.7/95/70 DZL1.4-0.7/95/70 DZL1.4-1.0/115/70 |
DZL28-1.0/115/70 DZL2.8-1.25/130/70 |
DZL4.2-1.0/115/70 DZL4.2-1.25/130/70 |
||
Rated Capacity T/h | 0.7 | 1.4 | 2.8 | 4.2 | ||
Rated Working Pressure Mpa | 0.7 | 0.7/1.0 | 1.0/1.25 | 1.0/1.25 | ||
Rated Steam Temp. ℃ | 95 | 95/115 | 115/130 | 115/130 | ||
Feed Water Temp. ℃ | 70 | 70 | 70 | 70 | ||
Fuel Consumption Kg/H | ~150 | ~310 | ~590 | ~900 | ||
Thermal Efficiency % | 75 | 78 | 79 | 77.44 | ||
Heating Surface | Boiler Body m² | 32.4 | 33.85 | 75.75 | 142 | |
Economizer m² | 24.64 | 38.5 | 87.2 | |||
Grate area m² | 1.4/2.05 | 2.3/3.5 | 4.66 | 7.4 | ||
Designed Fuel Type | Bituminous Coal | Bituminous Coal | Bituminous Coal | Bituminous Coal | ||
Max. Transport Weight T | ~16 | ~21 | ~26.5 | ~30 | ||
Max. Transport Dimension m | 4.3×2.25×2.955.26×2.25×2.95 | 5.1×2.2×3.35.9×2.2×3.3 | 6.5×2.6×3.5 | 6.01×3.4×3.57.29×2.9×1.7 | ||
Boiler Auxiliary Equipment Model and Specification | ||||||
Air Blower | Model | T4-72-11;3.2A Right | T4-72-11;3.5A Right | T4-72-11;4A Right | T4-72-11;5A Right | |
Motor Power | N=1.5 Kw | N=3 Kw | N=5.5 Kw | N=11 Kw | ||
Draft Fan | Model | YX9-355C ; Right 0° | Y-9-26;6.3C ; Right 0° | Y-9-26;9D;Right 0° | Y8-399D;Ring 0° | |
Motor Power | N=5.5 Kw | N=11 Kw | N=22 Kw | N=30 Kw | ||
Gear Box | Model | GL-5P | GL-5P | GL-5P | GL-10P | |
Motor Power | N=0.55 Kw | N=0.55 Kw | N=0.55 Kw | N=1.1Kw | ||
Feed Water Pump | Model | 1.5WCT-120 | 1.5WCT-120 | 1½ GC5x5 | 2GC5x4 | |
Motor Power | N=2.2 Kw | N=2.2Kw | N=5.5 Kw | N=11 Kw | ||
Dust Remover | Model | XD-1 | XD-2 | XD-4 | XD-6 |
ModelItem | DZL7-1.0/115/70 | DZL14-1.0/115/70 | DZL29-1.25/130/70 | DZL46-1.25/130/70 | DZL58-1.25/130/70 | DZL70-1.25/130/70 | |
Rated Capacity T/h | 7 | 14 | 29 | 46 | 58 | 70 | |
Rated Working Pressure Mpa | 1.0 | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | |
Rated Steam Temp. ℃ | 115 | 115 | 130 | 130 | 130 | 130 | |
Feed Water Temp. ℃ | 70 | 70 | 70 | 70 | 70 | 70 | |
Heating AreaBoiler Body m² | 228.6 | 434.7 | Radiation:73.07Convection:903.01 | Radiation:147.8Convection:1418.5 | Radiation:147.8Convection:1418.5 | Radiation:147.8Convection:1418.5 | |
Grate area m² | 11.5 | 22.5 | 34.5 | 57.8 | 77 | 91 | |
FuelKj/Kg | Coal | Class II Bituminous Coal | |||||
Low heat | 18757 | 17693 | |||||
Fuel Consumption Kg/h | ~1440 | ~2700 | ~6610 | ~10500 | ~12800 | ~15300 | |
Thermal Efficiency % | 80 | 80 | 82.5 | 82.05 | 83.03 | 83.28 | |
Max. Transport Weight Ton | 35 | 28 | 19.68 | 28.796 | 31 | 31 |
Product detail pictures:
Related Product Guide:
Boiler Structure
With this motto in mind, we've got become among essentially the most technologically innovative, cost-efficient, and price-competitive manufacturers for China Steam Boiler Electric Factories - Single Drum Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: Bangladesh, Eindhoven, El Salvador, Upon today, we have customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the highest quality products with best price. We are looking forward to doing business with you!
By Judy from Guinea - 2018.12.10 19:03
As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
By Cindy from Malaysia - 2017.02.18 15:54
Write your message here and send it to us