Good quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is regularly observed and pursued by our company for biomass boiler cylinder, Industrial Water Boiler, condensate pipingsteam boiler pipingsteam pipe linesteam jacketed pipesteam boiler pipingpipe for steam, We are going to empower people by communicating and listening, Setting an example to others and learning from experience.
Factory Free sample Outdoor Coal Boiler - Biomass Hot Water Boiler – Double Rings Detail:

Introduction :

Biomass boiler is horizontal three-back water fire pipe composite boiler. The fuel can be Biomass,coal,wood,rice husk,shells,pellets,bagasse,waste etc..

Display

PELLETS SHELLS HUSK BIOMASS BOILER

Feature:

1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.

xiangqingpic

Parameter :

DZG(L)Bearing Pressure Hot water boiler

Main Technology Parameter List

Model DZG0.7-0.7/95/70
DZL0.7-0.7/95/70
DZG1.4-0.7/95/70
DZL1.4-0.7/95/70
DZL1.4-1.0/115/70
DZL28-1.0/115/70
DZL2.8-1.25/130/70
DZL4.2-1.0/115/70
DZL4.2-1.25/130/70
Rated Capacity T/h 0.7 1.4 2.8 4.2
Rated Working Pressure Mpa 0.7 0.7/1.0 1.0/1.25 1.0/1.25
Rated Steam Temp. 95 95/115 115/130 115/130
Feed Water Temp. 70 70 70 70
Fuel Consumption  Kg/H ~150 ~310 ~590 ~900
Thermal Efficiency  % 75 78 79 77.44
Heating Surface Boiler Body  32.4 33.85 75.75 142
Economizer  24.64 38.5 87.2
Grate area   m² 1.4/2.05 2.3/3.5 4.66 7.4
Designed Fuel  Type Biomass Biomass Biomass Biomass
Max. Transport Weight  T ~16 ~21 ~26.5 ~30
Max. Transport Dimension  m 4.3×2.25×2.955.26×2.25×2.95 5.1×2.2×3.35.9×2.2×3.3 6.5×2.6×3.5 6.01×3.4×3.57.29×2.9×1.7

 

 

Model DZL7-1.0/115/70 DZL14-1.0/115/70 DZL29-1.25/130/70 DZL46-1.25/130/70 DZL58-1.25/130/70 DZL70-1.25/130/70
Rated Capacity T/h 7 14 29 46 58 70
Rated Working Pressure Mpa 1.0 1.0 1.25 1.25 1.25 1.25
Rated Steam Temp. 115 115 130 130 130 130
Feed Water Temp. 70 70 70 70 70 70
Heating AreaBoiler Body 228.6 434.7 Radiation:73.07Convection:903.01 Radiation:147.8Convection:1418.5 Radiation:147.8Convection:1418.5 Radiation:147.8Convection:1418.5
Grate area   m² 11.5 22.5 34.5 57.8 77 91
Fuel Consumption Kg/h ~1440 ~2700 ~6610 ~10500 ~12800 ~15300
Thermal Efficiency  % 80 80 82.5 82.05 83.03 83.28
Max. Transport Weight  Ton 35 28 19.68 28.796 31 31

Note: Parameter is just for reference, the exact parameter should follow the factory technical data.


Product detail pictures:

Factory Free sample Outdoor Coal Boiler - Biomass Hot Water Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

The pretty loaded projects management experiences and one to a person support model make the high importance of business enterprise communication and our easy understanding of your expectations for Factory Free sample Outdoor Coal Boiler - Biomass Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: Russia, Swiss, Milan, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Ingrid from Oman - 2017.07.07 13:00
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Rose from Burundi - 2018.09.23 18:44
    Write your message here and send it to us

    Related products

    • Super Purchasing for Coal Fired Boilers - Coal Boiler Biomass Boiler I.D.Fan – Double Rings

      Super Purchasing for Coal Fired Boilers - Coal...

      I.D fan used in Coal Boiler boiler induced draft fan is designed for the industrial boiler (1-20T / h) or domestic boiler equipped with various coal quality and smoke and dust removal device. It can be selected for the same air inlet conditions and performance, but the high temperature is ≤ 250 ℃. Before induced draft, a dust removal device with efficiency ≤ 85% must be installed to ensure that the dust content of flue gas entering the fan is 400mg/m3

    • China Heat Boilers Manufacturers - heat recovery boiler – Double Rings

      China Heat Boilers Manufacturers - heat recove...

      Introduction: Main Performance Parameter List Steam Pressure 1.0~2.5 Mpa Inlet Temperature 250℃ Saturation Temperature 179℃ Heating Water:Inlet Temperature 90℃; Outlet Temperature 140℃

    • China Gold Supplier for Boiler Manufacturing - Well-designed Biomass Pellet Boiler - Coal Boiler Biomass Boiler Reducer – Double Rings – Double Rings

      China Gold Supplier for Boiler Manufacturing -...

      Reducer used in DR Boiler • The main parts adopt high quality carbon structural refined steel.With high strength, high transmission efficiency and reliable operation, long service life, etc. • Respectively using multilevel, stepless frequency conversion speed regulating mode. User can reasonably match speed reducer according to the different operation condition of boiler.With the features of easy operation, energy saving, etc • With characteristics of large transmission torque and speed...

    • Trending Products Boiler System - Double Drum Hot Water Boiler – Double Rings

      Trending Products Boiler System - Double Drum ...

      Parameter : SZL Bearing Pressure Hot water Boiler Main Technology Parameter List ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 115/130 115/130 115/130 Feed Water Temp. ℃ 70 70 70 Fuel Consumption  Kg/H ~580 ~900 ~1130 Thermal Efficiency  % 78 80 80 Heating Surface Boil...

    • Wood Poles Autoclave Factory - Boiler Valve and Meter – Double Rings

      Wood Poles Autoclave Factory - Boiler Valve an...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • Wholesale Industry Boiler - Gas oil Boiler Economizer – Double Rings

      Wholesale Industry Boiler - Gas oil Boiler Eco...

      More photo Boiler economizers are heat exchange devices with finned tubes that heat a liquid, sometimes water, up to however sometimes doesn’t exceed the boiling purpose of liquid. We can manufacture three types of boiler economizer, bare tube economizer, H finned tube economizer and spiral finned tube economizer. H-finned tube economizer is high efficient heat exchanger economizer which is consisted of H-finned tubes.