Our company insists all along the quality policy of "product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff" and the consistent purpose of "reputation first, customer first" for chinese vertical boiler, water pipe boiler, Thermal Oil Boiler, Living by good quality, enhancement by credit history is our eternal pursuit, We firmly feel that soon after your visit we will become long-term associates.
Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings Detail:

Used in Boiler

DZL 6-1.25-AII STEAM BOILER Installation Material List

  Flange Stop Valve

  Item  Description   Quantity
1 DN 150    1.6 MPA 1 PC
2 DN 100    1.6 MPA 1 PC
3 DN 80     1.6 MPA 1 PC
4 DN 65     1.6 MPA 2 PCS
5 DN 50     1.6 MPA 3 PCS
6 DN 40     1.6 MPA 1 PC
7 DN 15     1.6 MPA 1 PC

  Flange Check Valve

  Item  Description   Quantity
1 DN 50     1.6 MPA 1 PC

  Flange

  Item  Description   Quantity
1 DN 150      2 PCS
2 DN 100       30 PCS
3 DN 80      1 PC
4 DN 65       2 PCS
5 DN 50       20 PCS
6 DN 40       8 PCS
7 DN 15       1 PC

  Screw Ball Valve

  Item  Description   Quantity
1 DN 40     1.6 MPA 3 PCS
2 DN 15     1.6 MPA 3 PCS
3 DN 20     1.6 MPA 2 PCS

  Movable Joint (Use in Water Pump)

  Item  Description   Quantity
1 DN 40     2 PCS
2 DN 20       1 PC

 Six-Wing Screw (Double-Head)(Use in Water Pump)

  Item  Description   Quantity
1 DN 40      6 PCS
2 DN 20       4 PCS
3 DN 15 2 PCS

  Pressure Gauge

  Item  Description   Quantity
1 Φ 150  0~1.6Mpa 1 PC
2 Φ 150  0~2.5Mpa 1 PC
3  Pressure Gauge Elbow Pipe 2 PCS
4  Three Way Cock   2 pcs

 Graphite Steel Cushion

  Item  Description   Quantity
1 DN 150   6 PCS
2 DN 100     6 PCS
3 DN 80 10 PCS
4 DN 65       6 PCS
5 DN 50       4 PCS
6 DN 40       10 PCS
7 DN 25       20 PCS
8 DN 20       4 PCS
9 DN 15       4 PCS

  Bolt

  Item  Description  Quantity
1 M 20X65 50 Sets
2 M 18X65 50 Sets
3 M 16X60 240 Sets
4 M 16X50 100 Sets
5 M 12X50 100 Sets
6 M 12X40 200 Sets
7 M 10X40 200 Sets
8 M 20X400 (Stone Bolt use for Chimney) 10 Sets

  Seamless Steal Tube

  Item  Description   Quantity
1  Φ 159 12 meter
2  Φ 108 12 meter
3  Φ 57  30 meter
4  Φ 45 6 meter
5  Φ 76 12 meter
6  Φ 22 12 meter

  Elbow  

  Item  Description  Quantity
1  Φ 159 3 PCS
2  Φ 100 3 PCS
3  Φ 76  2 PCS
4  Φ 57 15 PCS
5  Φ 45 4 PCS
6  Φ 22 2 PCS

 Screw Elbow Use in Pipe of Water Pump

  Item  Description  Quantity
1 DN 40   4 PCS
2 DN 20     2 PCS

 Screw Three-way Use in Pipe of Water Pump

  Item  Description  Quantity
1 DN 40   2 PCS

 Asbestos Rope

 Item  Description  Quantity
1  Asbestos  rope 10 Kg

 


Product detail pictures:

Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings detail pictures

Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings detail pictures

Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings detail pictures

Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Sticking towards the principle of "Super High-quality, Satisfactory service" ,We've been striving to become a superb business partner of you for Factory Outlets Thermal Oil Boiler - Boiler Installation Material – Double Rings , The product will supply to all over the world, such as: Morocco, Mozambique, Iceland, We have been perfectly devoted to the design, R&D, manufacture, sale and service of hair products during 10 years of development. We have introduced and are making full use of internationally advanced technology and equipment, with advantages of skilled workers. "Dedicated to providing reliable customer service" is our aim. We are sincerely looking forward to establishing business relationships with friends from at home and abroad.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Laura from Buenos Aires - 2017.09.26 12:12
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Helen from Greece - 2018.09.23 17:37
    Write your message here and send it to us

    Related products

    • China Outdoor Coal Boiler Factory - DHL Corner Tube Bulk Water Pipe Boiler – Double Rings

      China Outdoor Coal Boiler Factory - DHL Corner...

      Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

    • Reasonable price Boiler Power Plant - Gas Steam Boiler – Double Rings

      Reasonable price Boiler Power Plant - Gas Stea...

      Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

    • Bottom price Industrial Hot Water Boiler - Gas oil Boiler Burner – Double Rings

      Bottom price Industrial Hot Water Boiler - Gas...

      More photos •Single stage operation(on/off). •Air-gas mixing at blast-pipe. •Ability to obtain optimal combustion values by regulating combustion air and blast-pipe. •Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler. •Single stage manual flow adjustment •Sliding/modulating The servo motor which fixed with a cam can adjust the consumption for fuel and air. •One flange and one insulating seal for boiler fasten...

    • Hot Selling for Oil Fired Boiler - Boiler Electric Control – Double Rings

      Hot Selling for Oil Fired Boiler - Boiler Elec...

      More Photos Electric Control Container Overview 2-4T 6T 10T 15T 20T 25T Sheet 1: 2t steam boiler electrical instrument control system configuration (common configuration 1.25Mpa) Features name Specification unit Qty Brand Electrical control           Induced draft fan control 11KW  Star Delta Start  set  1  Zhengtai Blower control  3KW  Direct start  set  1  Grate control  0.55KW  Direct start  set  1  Coal machine control 1.1KW  Direct start  set  1  Slag machine control ...

    • Factory source Natural Gas Steam Boiler - Boiler Electric Control – Double Rings

      Factory source Natural Gas Steam Boiler - Boil...

      More Photos Electric Control Container Overview 2-4T 6T 10T 15T 20T 25T Sheet 1: 2t steam boiler electrical instrument control system configuration (common configuration 1.25Mpa) Features name Specification unit Qty Brand Electrical control           Induced draft fan control 11KW  Star Delta Start  set  1  Zhengtai Blower control  3KW  Direct start  set  1  Grate control  0.55KW  Direct start  set  1  Coal machine control 1.1KW  Direct start  set  1  Slag machine control ...

    • Industrial Boiler Ltd Suppliers - Coal Boiler Biomass Boiler I.D.Fan – Double Rings

      Industrial Boiler Ltd Suppliers - Coal Boiler ...

      I.D fan used in Coal Boiler boiler induced draft fan is designed for the industrial boiler (1-20T / h) or domestic boiler equipped with various coal quality and smoke and dust removal device. It can be selected for the same air inlet conditions and performance, but the high temperature is ≤ 250 ℃. Before induced draft, a dust removal device with efficiency ≤ 85% must be installed to ensure that the dust content of flue gas entering the fan is 400mg/m3