go on to boost, to be certain item quality in line with market and buyer standard demands. Our firm has a excellent assurance procedure happen to be established for electric steam generator, coal boiler F.D fan, chinese economizer, If possible, be sure to send your needs with a detailed list including the style/item and quantity you require. We will then deliver our greatest price ranges to you.
Factory Supply Steam Tube - AAC Autoclave and Boiler – Double Rings Detail:

Autoclave Characteristics

1 The autoclave is steel horizontal tube-type device, the autoclave lid is pressed by the whole block 16MnR steel, the flange of autoclave body and autoclave lid is used the 16Mn steel in the whole forging processing. The weld parts have been heat treatment and strict nondestructive testing in accordance with relevant standards.
2. Autoclave door is activity Open structure by hand-reducer. The clients can also choice the electric, pneumatic, hydraulic style to open and close.
Equipped with a perfect safety interlock protection device to maximum avoid mistake operation, and to ensure the safe operation of the autoclave and operator safety production.
The autoclave door has two types for the user to choose : 1. Side open 2. Up Open. Side open style adopts Rotating arm side open door structure, rotating flexible, low place operating , easy to operate . Up Open style adopts leveraged open door structure, the lower end of leverage connect with the autoclave door , the upper end equipped lift equipment, this type is portable to open, and small space in the autoclave side.
3. The autoclave door seal is imported rubber seals by professional manufacturers , simple installation, good sealing and long service life.
The autoclave body bearing has equipped the three style of fixed bearing, move bearing and end special bearing in different parts. It is best to be suitable for the thermal expansion and contraction of autoclave, to ensure the normal work of the autoclave and useful life.
4. The autoclave has a safety valve, pressure gauge, temperature measurement devices, inlet and exhaust valves, sealing ball valves, steam traps and other necessary valves and instrumentation, and equipped with decontamination tank for the user optional.
5. Besides the normal steam distribution pipes and guide rails, we specially set up the sealed steam protection cover and
Conventional steam distribution pipes and rails parts except the kettle, we more the sake of customers, set up a special sealed vapor scour protection cover and drain cover.
6. The autoclave design advanced and rigorous production, strictly follow the National Pressure Vessel Code.

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

Factory Supply Steam Tube - AAC Autoclave and Boiler – Double Rings detail pictures

Factory Supply Steam Tube - AAC Autoclave and Boiler – Double Rings detail pictures

Factory Supply Steam Tube - AAC Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

We have state-of-the-art tools. Our products are exported towards the USA, the UK and so on, enjoying a fantastic reputation amongst customers for Factory Supply Steam Tube - AAC Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Dubai, Senegal, Thailand, With the highest standards of product quality and service, our products have been exported to more than 25 countries like the USA, CANADA, GERMANY, FRANCE, UAE, Malaysia and so on.We are very pleased to serve customers from all over the world!
  • After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Heather from Angola - 2017.01.11 17:15
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Penny from Accra - 2017.10.25 15:53
    Write your message here and send it to us

    Related products

    • Natural Gas Steam Boiler Suppliers - Coal Boiler Chain Grate – Double Rings

      Natural Gas Steam Boiler Suppliers - Coal Boil...

      More phtos The patent material  RTSiCr,RQTSi4Mo which is our company’s unique material. High temperature resistance, Special process, longer service life.   Travelling type grate stoker Spare Parts—Grate Bar The structure is simple, the metal consumption is small, the ventilation section ratio is large, and the strength and performance requirements of the driving shaft, the driven shaft and the grate are high.

    • OEM China Diesel Hot Water Boiler - Boiler Water Treatment – Double Rings

      OEM China Diesel Hot Water Boiler - Boiler Wat...

      More photos 1. Quartz sand filter — mainly used for the removal of sediment from water. 2. Active Carbon filter– mainly used for chlorine removal and other organic gases and to clear up the taste of water . 3. Water Softener– exchange “ions” of calcium and magnesium with the most common and easiest method. 4. Precision filter– mainly used for removing microorganisms,chlorine,part of the heavy metal ions more precisely 5. High pressure pump– Provi...

    • Factory Price For Biomass Fired Boiler - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      Factory Price For Biomass Fired Boiler - Coal ...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

    • Odm Engineering Oil Pump Suppliers - Wood Biomass Boiler – Double Rings

      Odm Engineering Oil Pump Suppliers - Wood Biom...

      Korean Purchased two sets Biomass Boiler Type: DZL 4-1.25-S  ; SZL 10-1.25-S ; Fuel : Wood Chip, Wood ,Plywood chip etc. Usage : Plywood Factory

    • China Electric Steam Generator - Oil Steam Boiler – Double Rings

      China Electric Steam Generator - Oil Steam Boi...

      Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

    • Lowest Price for Oil Condensing Boilers - Coal Boiler Biomass Boiler I.D.Fan – Double Rings

      Lowest Price for Oil Condensing Boilers - Coal...

      I.D fan used in Coal Boiler boiler induced draft fan is designed for the industrial boiler (1-20T / h) or domestic boiler equipped with various coal quality and smoke and dust removal device. It can be selected for the same air inlet conditions and performance, but the high temperature is ≤ 250 ℃. Before induced draft, a dust removal device with efficiency ≤ 85% must be installed to ensure that the dust content of flue gas entering the fan is 400mg/m3