Gas Hot Water Boiler China - SZS Fulverized Coal Steam Boiler Hot water boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

"Sincerity, Innovation, Rigorousness, and Efficiency" is definitely the persistent conception of our corporation to the long-term to establish alongside one another with customers for mutual reciprocity and mutual profit for stainless water pump, Heating Water Boiler, Hot Water Heating Boilers, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Gas Hot Water Boiler China - SZS Fulverized Coal Steam Boiler Hot water boiler – Double Rings Detail:

Introduction:

As a new type of mature high-performance with low-pollution clean coal technology.
circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics.
1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfurization rate is economical.
2. Circulating fluidized bed boiler could adopt various coal types and has high combustion efficiency, which is especially suitable for low quality, low calorific value coal.
3.The ash of circulating fluidized bed boiler is of high activity, thus it is easy to realize comprehensive utilization without secondary pollution.
4.Circulating fluidized bed boiler could adjust its load in a wide range. Lowest load can be reduced to 30% Of full capacity.
Our recommendation—the of low magnification circulating fluidized bed boiler products have completely solved the problems like boiler abrasion, slagging and ash blocking of feed recycle device.original emission concentration of boiler and deslagging. Now the requirement on environmental protection is increasingly strict.As raw coal’s proportion of direct-fired is high. which makes the contradiction between coal and environmental protection more and more acute. Under such background, circulating fluidized bed boiler with the features of environmental protection and energy saving is your best choice.

Quality Control

1 Strength Calculation Report for Applied Materials after Inspection Machine inspected.
2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod;
3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler;
4 Hydraulic test report:ensure the standard working pressure and safety;
5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province
6 Manufacturer Produce Level  Grade-A.  Product Reach European Standard CE Marks.

Inspection Machinery for the Boiler in Workshop and Laboratory :

No. Name Model Qty
1 Digital Carbon & Sulfur Analysis Meter HV-4B 1set
2 High Speed Self-Ignition Furnace HB-2H 1set
3 Electric Scale JA1003 1set
4 Photometer 723 1set
5 Metallography Scale XJB-2A 1set
6 Hydraulic Multi-propose Test Machinery WE-100 1set
7 WE-600A 1set
8 Concussion Testing Machine JB-30 1set
9 Projective Meter JS 1set
10 X Ray Crack Detector XXH3005 1set
11 XXH2505 XXXXH23005 2sets
12 XY2515 2sets
13 Ultrasonic Crack Detector CTS-22 2sets

Product detail pictures:


Related Product Guide:
Boiler Structure

Our company has been concentrating on brand strategy. Customers' pleasure is our greatest advertising. We also source OEM service for Gas Hot Water Boiler China - SZS Fulverized Coal Steam Boiler Hot water boiler – Double Rings , The product will supply to all over the world, such as: Mauritius, Slovakia, Spain, Our Company policy is "quality first, to be better and stronger, sustainable development" . Our pursuit goals is "for society, customers, employees, partners and enterprises to seek reasonable benefit". We aspirate to do cooperate with all different the auto parts manufacturers, repair shop, auto peer , then create a beautiful future! Thank you for taking time to browse our website and we would welcome any suggestions you may have that can help us to improve our site.
We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
5 Stars By Prudence from Greek - 2018.09.23 18:44
This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
5 Stars By Audrey from Gambia - 2018.06.03 10:17
Write your message here and send it to us

Related products

  • China Industrial Boiler Suppliers - Installation & Technology Service – Double Rings

    China Industrial Boiler Suppliers - Installati...

    Installation Procedure Step 1. Slag Extruder put into Foundation| Step 2. Lift Boiler Body to Foundation . Then install the Platform and Stair. Step 3.Connect Boiler,Economizer (Down Part) and Gas Flue. Step 4. Connect Economizer ( Up Parts) and Gas Flue. Step 5.Use asbest rope to Fix Economizer and Gas Flue. Keep no gas leak. Step 6. Lift Dust Cleaner to Foundation. Step 7.Connect and fix the Gas Flue between Dust Cleaner and Economizer . Step 8. Lift I.D Fan to Foundation Step...

  • OEM Factory for Lpg Steam Boiler - Oil Steam Boiler – Double Rings

    OEM Factory for Lpg Steam Boiler - Oil Steam B...

    Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

  • China Thermal Oil Boiler Factory - Boiler Flue – Double Rings

    China Thermal Oil Boiler Factory - Boiler Flue...

    Used in Boiler Introduction Industrial smoke exhaust, air into the pipe, the pipe is equipped with a damper (valve) to regulate the wind speed and pressure in the pipe. It is composed of furnace wall, partial heating surface pipe and cladding wall pipe to guide the flow of smoke, and through each heating surface for heat exchange, divided into horizontal flue and tail flue. The main smoke duct section size of the large capacity boiler is very large, in order to bear and transfer the loa...

  • Wholesale Diesel Steam Boiler - SZS Fulverized Coal Steam Boiler Hot water boiler – Double Rings

    Wholesale Diesel Steam Boiler - SZS Fulverized...

    Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

  • 2020 wholesale price Wood Chip Biomass Boiler - Biomass Steam Boiler – Double Rings

    2020 wholesale price Wood Chip Biomass Boiler -...

    Biomass Boiler-Hot Sale- Easy Installation Low Heating Value Fuel Wood Rice Husk Pellets etc. Introduction : Biomass Steam Boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover. The hopper of fuel drops to ...

  • One of Hottest for Boiler Wood - Coal Boiler Biomass Boiler I.D.Fan – Double Rings

    One of Hottest for Boiler Wood - Coal Boiler B...

    I.D fan used in Coal Boiler boiler induced draft fan is designed for the industrial boiler (1-20T / h) or domestic boiler equipped with various coal quality and smoke and dust removal device. It can be selected for the same air inlet conditions and performance, but the high temperature is ≤ 250 ℃. Before induced draft, a dust removal device with efficiency ≤ 85% must be installed to ensure that the dust content of flue gas entering the fan is 400mg/m3