Low MOQ for Hot Water Heating Boilers - Gas/Oil Fired Hot Water Boiler – Double Rings
Low MOQ for Hot Water Heating Boilers - Gas/Oil Fired Hot Water Boiler – Double Rings Detail:
Introduction :
WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney.
There are the front and back Smokebox Cap in the boiler, easy to maintenance.
Excellent burner adopts combustion automatic ratio adjustment , feedwater automatic control, start and stop program , automatic operation and other advanced technology, also has the High&Low water level alarm and protection function of Extreme low water levels, ultra-high pressure, turn off etc..
The boiler has the features of compact structure, safe and reliable, simple operation, quick installation, less pollution, low noise, and high efficiency.
Feature:
1.Overall structure is reasonable and compact, easy to install.
The boiler is composed of Boiler body, chimney and piping system. The boiler body and chimney have been finished in the factory, the pipe, valve and gauge in the boiler have also been completed in the factory. The clients only need to assemble the boiler and chimney together , connect the gas ,power, water and then
to test run , greatly shorten the installation time, and ensure the quality of the boiler.
2. Advanced design, the whole structure, combustion chamber assemble in Front smokebox cover, the body has the heating surface and combustion chamber. It is the reasonable structure, compact, low consumption of steel , the furnace gall is bias wave form furnace, the insulation layer is new thermal insulation materials, color sheet packaging, packaging shape is rectangular, the boiler performance, weight, structure, size, shape modeling is more advanced and perception .
The feed water device equip on the right side of the boiler base , the whole structure, do not need another foundation.
3. Simple water cycle, reasonable structure of pressure parts, guarantee water quality, safe to run
4. Complete Ancillary equipment, advanced comprehensive technology
Parameter
WNS Hot Water Boiler burning oil or gas
Main Technology Parameter List
ModelItem | WNS0.35-0.7/95/70-YQ | WNS0.7-0.7/90/70-YQ | WNS1.05-0.7/95/70-YQ | WNS1.4-0.7/95/70-YQ | WNS2.1-0.7/95/70-YQ | |
Rated Capacity Mw |
0.35 |
0.7 |
1.05 |
1.4 |
2.1 |
|
Rated Working Pressure |
0.7 Mpa |
0.7 Mpa |
0.7 Mpa |
0.7 Mpa |
0.7 Mpa | |
Output Water Temp. ℃ |
95 |
95 |
95 |
95 |
95 |
|
Return Water Temp. ℃ |
70 |
|||||
Heating Surface m² |
12.05 |
30.7 |
45.5 |
60.9 |
90.5 |
|
Exhaust gas Temp. ℃ |
180 |
180 |
178 |
181 |
179 |
|
Thermal Efficiency % |
84 |
85 |
86 |
88 |
88 |
|
Design Fuel |
Diesel Oil/Heavy Oil/Natural Gas/Liquid Gas/Town Gas |
|||||
Ringelmann shade |
< Grade 1 |
|||||
FuelConsumption
Kg/h (Nm3/h) |
Diesel Oil |
31 |
62.5 |
93.66 |
124.75 |
187.11 |
Heavy oil |
33.5 |
66.99 |
98.89 |
131.72 |
197.55 |
|
Liquid gas |
36 |
72.2 |
108.23 |
144.16 |
216.21 |
|
Town gas |
74 |
144 |
216.5 |
288.3 |
432.4 |
|
Boiler Weight Ton | Empty |
2.562 |
4.95 |
5.5 |
7.34 |
10.1 |
Full Water |
3.162 |
6.5 |
7.6 |
12.8 |
16 |
|
Power Source V | 380V/50Hz |
ModelItem | WNS2.8-1.0/115/70WNS2.8-1.25/130/70 | WNS3.5-1.0/115/70WNS3.5-1.25/130/70 | WNS4.2-1/115/70 WNS4.2-1.25/130/70 | WNS5.6-1/115/70WNS5.6-1.25/130/70 | WNS7-1/115/70WNS7-1.25/130/70 | |
Rated Capacity Mw |
2.8 |
3.5 |
4.2 |
5.6 |
7 |
|
Rated Working Pressure | 1.0/1.25 Mpa |
1.0/1.25 Mpa |
1.0/1.25 Mpa |
1.0/1.25 Mpa |
1.0/1.25 Mpa | |
Output Water Temp. ℃ |
115/130 |
115/130 |
115/130 |
115/130 |
115/130 |
|
Return Water Temp. ℃ |
70 |
|||||
Heating Surface m² |
124.7 |
137 |
145 |
165 |
210 |
|
Exhaust gas Temp. ℃ |
180.5 |
180 |
179 |
178.5 |
182 |
|
Thermal Efficiency % |
88 |
89 |
89 |
90 |
90 |
|
Design Fuel |
Diesel Oil/Heavy Oil/Natural Gas/Liquid Gas/Town Gas |
|||||
Ringelmann shade |
< Grade 1 |
|||||
FuelConsumption
Kg/h (Nm3/h) |
Diesel Oil |
249.21 |
311.17 |
373.41 |
497.78 |
621 |
Heavy oil |
263.12 |
328.55 |
394.26 |
525.57 |
680 |
|
Liquid gas |
287.98 |
359.58 |
431.5 |
575.2 |
719.17 |
|
Town gas |
575.96 |
719.16 |
863 |
1151 |
1438 |
|
Boiler Weight Ton | Empty |
13.9 |
14.5 |
15.1 |
19.1 |
19.7 |
Full Water |
22.5 |
24.9 |
25.5 |
31.8 |
37 |
|
Power Source V | 380V/50Hz |
Product detail pictures:
Related Product Guide:
Boiler Structure
We are proud of the superior customer gratification and wide acceptance due to our persistent pursuit of top of the range both of those on merchandise and service for Low MOQ for Hot Water Heating Boilers - Gas/Oil Fired Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: Moldova, Croatia, Karachi, Our tenet is "integrity first, quality best". We have confidence in providing you with excellent service and ideal products. We sincerely hope we can establish win-win business cooperation with you in the future!
By Gill from India - 2018.06.18 17:25
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
By Jerry from Manila - 2018.06.30 17:29