Manufactur standard Electric Steam Generator - Autoclave and Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

Innovation, excellent and reliability are the core values of our firm. These principles today more than ever form the basis of our success as an internationally active mid-size corporation for Steam & Hot Water Pipe, coal boiler water pool, Oil Fueled Boiler, If you are interested within our products and solutions, you should come to feel absolutely free to ship us your inquiry. We sincerely hope to ascertain win-win company relationships with you.
Manufactur standard Electric Steam Generator - Autoclave and Boiler – Double Rings Detail:

Autoclave-Popular used in ACC Plant,Flyash Plant,Building Material etc..

Autoclave Feature

1, the first domestic production of autoclave professional factory.
2, assembly line production, welding all the automation, quality and stability.
3, all the pressure components 100% X-ray film detection, advanced detection methods.
4, the product as a whole factory, advanced and reasonable structure, short installation period, the investment cost is low.
5, fully furnished, by manual or computer control.
    Autoclave use:
    Autoclave steam curing equipment for large, can be used for steam-cured sand lime bricks, fly ash bricks, aerated concrete blocks, high-strength concrete pole, pipe and other concrete products, but also for timber, medicine, chemical industry, glass, insulation materials and other industries.
autoclave and boiler ACC

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

Manufactur standard Electric Steam Generator - Autoclave and Boiler – Double Rings detail pictures

Manufactur standard Electric Steam Generator - Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our items are commonly identified and trusted by people and can fulfill repeatedly altering economic and social wants of Manufactur standard Electric Steam Generator - Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Finland, Johor, Puerto Rico, Our tenet is "integrity first, quality best". We have confidence in providing you with excellent service and ideal products. We sincerely hope we can establish win-win business cooperation with you in the future!
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Jean from Boston - 2017.02.28 14:19
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Edward from Jeddah - 2017.01.28 18:53
    Write your message here and send it to us

    Related products

    • China Gas Steam Boiler Manufacturer - Steam&Hot Water Pipe – Double Rings

      China Gas Steam Boiler Manufacturer - Steam&am...

      Products Description Structure Steel pipe– insulation layer–steel jacket pipe Steel pipe process 1. Seamless, 2. Spiral steel pipe( SAW) 3. Straight steel pipe(ERW) Insulation layer of external sliding type Fiberglass wool or rock wool Insulation layer of internal sliding type 1. Calcium silicate insulation material 2. Polyurethane insulation material Application 1. Steam 2. Hot oil 3. Hot material Specification DN57-1020mm(1 inch-64 inch) Medium temperature...

    • China Natural Gas Steam Boiler Manufacturers - Electric Steam Boiler – Double Rings

      China Natural Gas Steam Boiler Manufacturers -...

      Introduction: Pressure Vessel Main Performance Parameter List Steam Pressure1.0Mpa Inlet Temperature 250℃ Saturation Temperature 179℃ Heating Water:Inlet Temperature 90℃; Outlet Temperature 140℃ Feature Fully automatic operation can be realized by a digital controller switch Control system selected advanced programmable controller, heating element input sequence can be realized the timing automatically switches to extend component life With automatic sewage With automatic wa...

    • Top Suppliers Industrial Boiler Ltd - Double Drum Hot Water Boiler – Double Rings

      Top Suppliers Industrial Boiler Ltd - Double D...

      Parameter : SZL Bearing Pressure Hot water Boiler Main Technology Parameter List ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 115/130 115/130 115/130 Feed Water Temp. ℃ 70 70 70 Fuel Consumption  Kg/H ~580 ~900 ~1130 Thermal Efficiency  % 78 80 80 Heating Surface Boil...

    • Massive Selection for Wood Pellet Boiler - Coal Boiler Economizer – Double Rings

      Massive Selection for Wood Pellet Boiler - Coa...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer P...

    • Biomass Boiler Manufacturer - SZS Gas Oil PLG Boiler – Double Rings

      Biomass Boiler Manufacturer - SZS Gas Oil PLG ...

      Introduction : SZS series boiler body is longitudinal 2-drum, D-type chamber combustion strueture. The furnace is on right side and the convection bank tube is on left side. The body is fixed on the body chassis by flexible supports in the middle and two ends of the lower drum,can secure to let the whole boiler body to expand sideways. Surround furnace there are narrow space membrane cooling tube wall. It is totally sealed and separated between the membrane wall on furnace left side and the c...

    • Hot-selling Steam Pipe - Coal Boiler Biomass Boiler F.D.Fan – Double Rings

      Hot-selling Steam Pipe - Coal Boiler Biomass B...

      FD Fan used in Coal Boiler Industrial centrifugal blower fan is used for steam boilers, which has good quality and high efficiency. According to your requirements, we can provide technical solution and technical solution. Below industrial blower fan picture for your reference.