New Fashion Design for Biomass Steam Boiler - Single Drum Steam Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for veritcal coal fired boiler, Biomass Boiler Cost, Stoker Fired Boiler, And there are also a lot of overseas close friends who came for sight seeing, or entrust us to buy other stuff for them. You will be most welcome to come to China, to our city and to our manufacturing facility!
New Fashion Design for Biomass Steam Boiler - Single Drum Steam Boiler – Double Rings Detail:

Introduction :

Single Drum Chain Grate Coal fired boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover.
The hopper of fuel drops to grate bar, then enter furnace for burning, by the ashes room above the back arch, the flame gets through the first backhaul fire tube to front smokebox, then turn back from front smokebox to the second flue for economizer and dust collector, at last, released into the atmosphere by the draft fan through chimney.

dzl dzg Steam Boiler Equipment Layout

Feature:

1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.

xiangqingpic

Parameter :

DZG(L)Horizontal Type Coal-Burning Steam Boiler

Main Technology Parameter List

Model  DZG1-0.7-A II
DZG1-1.0-A II
DZG1-1.25-A II
DZG2-1.0-A II
DZG2-1.25-A II
DZG2-1.57-AII
DZG4-1.25-A II
DZG4-1.57-A II 
DZL1-0.7-A II
DZL1-1.0- A II
DZL1-1.25- A II
DZL1-1.57- A II
DZL1-2.45- A II
Rated Capacity T/h 1 2 4 1
Rated Working Pressure Mpa 0.7/1.0/1.25 1.0/1.25/1.57 1.25/1.57 0.7/1.0/1.25/1.57/2.45
Rated Steam Temp. 170/183/194 183/194/204 194/204 170/183/194/204/226
Feed Water Temp. 20 20 20 20
Fuel Consumption  Kg/H 170 330 600 170
Thermal Efficiency  % 77 77 78 78
Heating Surface m² Boiler Body 32.4 33.85 75.75 32.4
Economizer 12.51 24.64 38.5 12.51
Grate area   m² 1.37 2.3 2.05
Designed Fuel  Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max. Transport Weight  T 10.6 19.6 26.5 13.3
Max. Transport Dimension  m 4.75×2.1×2.6 5.7×3.4×4.6 5.49×2.6×3.5 5.65×2.1×2.6
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right225° T4-72-11;3.2A;Righ 315° T4-72-11;4A; Right 315° T4-72-11;3.2A; Right 225°
Motor Power N=1.5 Kw N=3 Kw N=5.5 Kw N=1.5 Kw
Draft Fan Model YX9-35-11;5C ; Right 0° Y-9-26;6.3C ; Right 0° Y-9-26;9D;Right 0° YX 9-35-11;5C; Right 0°
Motor Power N=5.5 Kw N=11 Kw N=22 Kw N=5.5 Kw
Gear Box Model GL-5P
Motor Power N=0.55 Kw
Feed Water Pump Model 1.5WCT-120 1½ GC5x7 1½ GC5x7 1.5WCT-120
Motor Power N=2.2 Kw N=7.5 Kw N=7.5 Kw N=2.2 Kw
Dust Remover Model XD-1 XD-2 XD-4 XD-1

 

Model DZL2-1.0-AII
DZL2-1.25-AII
DZL2-1.57-AII
DZL2-2.45-AII   
DZL4-1.25-AII
DZL4-1.57-AII
DZL4-2.45-AII 
DZL6-1.25-AII
DZL6-1.57-AII
DZL6-2.45-AII 
DZL8-1.57-AII DZL10-1.25-AII
DZL10-1.57-AII
DZL10-2.45-AII
Rated Capacity T/h 2 4 6 8 10
Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.57 1.25/1.57/2.45
Rated Steam Temp. 183/194/204/226 194/204/226 194/204/226 203.04 194/204/226
Feed Water Temp. 20 20 20/60 20 20/60
Fuel Consumption  Kg/H ~310 ~590 ~900 ~1200 ~1440
Thermal Efficiency  % 78 80 77.44 78 80.6
Heating Surface m² Boiler Body 33.85 75.75 142 205 347
Economizer 24.64 38.5 87.2 139.52
Grate area   m² 3.5 4.66 7.4 8.4 10.98
Designed Fuel Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max.Transport Weight  Ton 21 26.5 38 33 28/29
Max. Transport Dimension  m 5.9×2.2×3.3 6.5×2.6×3.524 7.4×3.2×4.2 8.1×3.2×4.2 7.6×3.2×3.5
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right315° T4-72-11;4A;Righ 315° T4-72-11;5A; Right 225° GG8-Na;7.1A; Right 225° 10TG811DRight 225°
Motor Power N=3 Kw N=5.5 Kw N=11 Kw N=11 Kw N=15 Kw
Draft Fan Model Y9-26;6.3C; Right 0° Y-9-26;9D; Right 0° Y-8-39;9D;Right 0° GY8-1;Na9.5D;Right 0° 10JY;9.5D; Right 0°
Motor Power N=11 Kw N=22 Kw N=30Kw N=37Kw N=45 Kw
Gear Box Model GL-5P GL-5P GL-10P GL-16P
Motor Power N=0.55 Kw N=0.55 Kw N=1.1 Kw N=1.1 Kw
Feed Water Pump Model 1½ GC 5×7 1½ GC 5×7 DG 6-25×7 2GC-5xT 1½ GC 6×6
Motor Power N=7.5 Kw N=7.5 Kw N=7.5 Kw N=22 Kw N=2.2 Kw
Dust Remover Model XD-2 XD-4 XD-6 XD-8 XD-10

Product detail pictures:


Related Product Guide:
Boiler Structure

Well-run gear, qualified revenue workforce, and superior after-sales companies; We've been also a unified huge loved ones, anyone persist with the organization benefit "unification, determination, tolerance" for New Fashion Design for Biomass Steam Boiler - Single Drum Steam Boiler – Double Rings , The product will supply to all over the world, such as: Argentina, Jakarta, Argentina, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
5 Stars By Bruno Cabrera from Adelaide - 2018.02.12 14:52
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
5 Stars By Laurel from Ecuador - 2017.09.22 11:32
Write your message here and send it to us

Related products

  • Factory wholesale Oil Condensing Boilers - Boiler Installation Material – Double Rings

    Factory wholesale Oil Condensing Boilers - Boi...

    Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...

  • Special Design for Biomass Boiler Cost - Single Drum Hot Water Boiler – Double Rings

    Special Design for Biomass Boiler Cost - Singl...

    Parameter : DZG(L)Bearing Pressure Hot water boiler Main Technology Parameter List Model DZG0.7-0.7/95/70 DZL0.7-0.7/95/70  DZG1.4-0.7/95/70 DZL1.4-0.7/95/70 DZL1.4-1.0/115/70 DZL28-1.0/115/70 DZL2.8-1.25/130/70 DZL4.2-1.0/115/70 DZL4.2-1.25/130/70 Rated Capacity T/h 0.7 1.4 2.8 4.2 Rated Working Pressure Mpa 0.7 0.7/1.0 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 95 95/115 115/130 115/130 Feed Water Temp. ℃ 70 70 70 70 Fuel Consumption  Kg/H ~150 ~310 ~590 ~900 Thermal Efficiency ...

  • China Thermal Oil Boiler Factories - Installation & Technology Service – Double Rings

    China Thermal Oil Boiler Factories - Installat...

    Installation Procedure Step 1. Slag Extruder put into Foundation| Step 2. Lift Boiler Body to Foundation . Then install the Platform and Stair. Step 3.Connect Boiler,Economizer (Down Part) and Gas Flue. Step 4. Connect Economizer ( Up Parts) and Gas Flue. Step 5.Use asbest rope to Fix Economizer and Gas Flue. Keep no gas leak. Step 6. Lift Dust Cleaner to Foundation. Step 7.Connect and fix the Gas Flue between Dust Cleaner and Economizer . Step 8. Lift I.D Fan to Foundation Step...

  • Leading Manufacturer for Bosch Boiler - Boiler Flue – Double Rings

    Leading Manufacturer for Bosch Boiler - Boiler...

    Used in Boiler Introduction Industrial smoke exhaust, air into the pipe, the pipe is equipped with a damper (valve) to regulate the wind speed and pressure in the pipe. It is composed of furnace wall, partial heating surface pipe and cladding wall pipe to guide the flow of smoke, and through each heating surface for heat exchange, divided into horizontal flue and tail flue. The main smoke duct section size of the large capacity boiler is very large, in order to bear and transfer the loa...

  • Big Discount Electric Hot Water Boilers - Biomass Wood Thermal Oil Boiler – Double Rings

    Big Discount Electric Hot Water Boilers - Biom...

    Thermal Oil Boiler used in Textile,Foods, Rubber ,Paper, Plastic, Wood, Building Materials etc. Feature: 1.Overall structure is reasonable and compact, easy to install. 2.Advanced design, Complete structure 3. Simple water cycle, reasonable structure of pressure parts, guarantee water quality, safe to run 4. Complete Ancillary equipment, advanced comprehensive technology

  • PriceList for Diesel Hot Water Boiler - Boiler Water Pump – Double Rings

    PriceList for Diesel Hot Water Boiler - Boiler...

    Water Pump used in Boiler Components in contact with water—made of  SS304 or SS316 Head:  4~305m Flow rate:0.4~240m^3/h Phase: single phase or three phase Power: 220V/380V Connection: flange or threaded