News

  • Thermal Oil Boiler Fire Prevention

    Thermal Oil Boiler Fire prevention ONE / Pipe burst fire The oil quality is poor, and the carbon residue index in the oil exceeds the standard. When the heat transfer oil is inadvertently mixed with moisture, impurities or other oils during storage, transportation or operation and maintenance, w...
    Read more
  • How to clear thermal Oil Boiler

    Thermal oil anti-coking and anti-scaling technology 1. Deteriorating oil quality accelerates boiler carbon deposition and coking During the use of the heat-conducting oil boiler, the chemical composition of the heat-conducting oil is prone to high-temperature oxidation, cracking and decomposition...
    Read more
  • Thermal Oil Boiler Trouble Solve

    Trouble Solve   1. Export oil temperature is over-temperature When the outlet oil temperature exceeds the set upper limit of outlet oil temperature by 20°C or exceeds 350°C, the computer flashes to display the over-temperature temperature, and the controlled equipment is forcibly shut down. ...
    Read more
  • Thermal Oil Boiler Precautions

    Precautions During the patrol inspection, attention should be paid to check whether there is any leakage around the heat-conducting oil furnace. There should be enough fire-fighting equipment equipped with oil and electrical appliances nearby, and water is not allowed as a fire extinguishing agent.
    Read more
  • How to shutdown Thermal Oil Boiler

    Shutdown operation 1. Normally shut down the furnace ①Gradually reduce the temperature, turn off the burner, and stop the combustion; ②When the temperature of the hot oil drops below 70℃, stop the operation of the hot oil circulating pump (refer to the water pump operation regulations); ③Turn off...
    Read more
  • How to Start Thermal Oil Boiler

      start up 1. Start the heat-conducting oil circulating pump (transport one and prepare one, refer to the operation rules of the water pump), and circulate normally for about 0.5 hours after starting the pump to stabilize the pressure; 2. Press the burner start button to observe whether the ...
    Read more
  • Check Thermal Oil Boiler before start

    Check before start   1. Whether the heating furnace and its surroundings are clean and free of debris, check whether the furnace body, burner, controller, fire hole, chimney, etc. are normal; 2. Reverse the process equipment and process, check whether the oil level of the expansion tank is a...
    Read more
  • Thermal Oil Boiler Security Countermeasures

    Security countermeasures (1) Ensure equipment safety The heat-conducting oil heating system should be managed as a pressure equipment, and the heating equipment must be intact, otherwise the consequences will be very serious. During use, the wall thickness and pressure strength of the equipment s...
    Read more