We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for horizontal thermal oil boiler, biomass boiler dust cleaner, Biomass Pellet Boiler, Teamwork is encouraged at all levels with regular campaigns. Our research team experiments on various developments in the industry for improvement in the products.
OEM Supply Water Tube Boilers - Single Drum Steam Boiler – Double Rings Detail:

Introduction :

Single Drum Chain Grate Coal fired boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover.
The hopper of fuel drops to grate bar, then enter furnace for burning, by the ashes room above the back arch, the flame gets through the first backhaul fire tube to front smokebox, then turn back from front smokebox to the second flue for economizer and dust collector, at last, released into the atmosphere by the draft fan through chimney.

dzl dzg Steam Boiler Equipment Layout

Feature:

1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.

xiangqingpic

Parameter :

DZG(L)Horizontal Type Coal-Burning Steam Boiler

Main Technology Parameter List

Model  DZG1-0.7-A II
DZG1-1.0-A II
DZG1-1.25-A II
DZG2-1.0-A II
DZG2-1.25-A II
DZG2-1.57-AII
DZG4-1.25-A II
DZG4-1.57-A II 
DZL1-0.7-A II
DZL1-1.0- A II
DZL1-1.25- A II
DZL1-1.57- A II
DZL1-2.45- A II
Rated Capacity T/h 1 2 4 1
Rated Working Pressure Mpa 0.7/1.0/1.25 1.0/1.25/1.57 1.25/1.57 0.7/1.0/1.25/1.57/2.45
Rated Steam Temp. 170/183/194 183/194/204 194/204 170/183/194/204/226
Feed Water Temp. 20 20 20 20
Fuel Consumption  Kg/H 170 330 600 170
Thermal Efficiency  % 77 77 78 78
Heating Surface m² Boiler Body 32.4 33.85 75.75 32.4
Economizer 12.51 24.64 38.5 12.51
Grate area   m² 1.37 2.3 2.05
Designed Fuel  Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max. Transport Weight  T 10.6 19.6 26.5 13.3
Max. Transport Dimension  m 4.75×2.1×2.6 5.7×3.4×4.6 5.49×2.6×3.5 5.65×2.1×2.6
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right225° T4-72-11;3.2A;Righ 315° T4-72-11;4A; Right 315° T4-72-11;3.2A; Right 225°
Motor Power N=1.5 Kw N=3 Kw N=5.5 Kw N=1.5 Kw
Draft Fan Model YX9-35-11;5C ; Right 0° Y-9-26;6.3C ; Right 0° Y-9-26;9D;Right 0° YX 9-35-11;5C; Right 0°
Motor Power N=5.5 Kw N=11 Kw N=22 Kw N=5.5 Kw
Gear Box Model GL-5P
Motor Power N=0.55 Kw
Feed Water Pump Model 1.5WCT-120 1½ GC5x7 1½ GC5x7 1.5WCT-120
Motor Power N=2.2 Kw N=7.5 Kw N=7.5 Kw N=2.2 Kw
Dust Remover Model XD-1 XD-2 XD-4 XD-1

 

Model DZL2-1.0-AII
DZL2-1.25-AII
DZL2-1.57-AII
DZL2-2.45-AII   
DZL4-1.25-AII
DZL4-1.57-AII
DZL4-2.45-AII 
DZL6-1.25-AII
DZL6-1.57-AII
DZL6-2.45-AII 
DZL8-1.57-AII DZL10-1.25-AII
DZL10-1.57-AII
DZL10-2.45-AII
Rated Capacity T/h 2 4 6 8 10
Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.57 1.25/1.57/2.45
Rated Steam Temp. 183/194/204/226 194/204/226 194/204/226 203.04 194/204/226
Feed Water Temp. 20 20 20/60 20 20/60
Fuel Consumption  Kg/H ~310 ~590 ~900 ~1200 ~1440
Thermal Efficiency  % 78 80 77.44 78 80.6
Heating Surface m² Boiler Body 33.85 75.75 142 205 347
Economizer 24.64 38.5 87.2 139.52
Grate area   m² 3.5 4.66 7.4 8.4 10.98
Designed Fuel Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max.Transport Weight  Ton 21 26.5 38 33 28/29
Max. Transport Dimension  m 5.9×2.2×3.3 6.5×2.6×3.524 7.4×3.2×4.2 8.1×3.2×4.2 7.6×3.2×3.5
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right315° T4-72-11;4A;Righ 315° T4-72-11;5A; Right 225° GG8-Na;7.1A; Right 225° 10TG811DRight 225°
Motor Power N=3 Kw N=5.5 Kw N=11 Kw N=11 Kw N=15 Kw
Draft Fan Model Y9-26;6.3C; Right 0° Y-9-26;9D; Right 0° Y-8-39;9D;Right 0° GY8-1;Na9.5D;Right 0° 10JY;9.5D; Right 0°
Motor Power N=11 Kw N=22 Kw N=30Kw N=37Kw N=45 Kw
Gear Box Model GL-5P GL-5P GL-10P GL-16P
Motor Power N=0.55 Kw N=0.55 Kw N=1.1 Kw N=1.1 Kw
Feed Water Pump Model 1½ GC 5×7 1½ GC 5×7 DG 6-25×7 2GC-5xT 1½ GC 6×6
Motor Power N=7.5 Kw N=7.5 Kw N=7.5 Kw N=22 Kw N=2.2 Kw
Dust Remover Model XD-2 XD-4 XD-6 XD-8 XD-10

Product detail pictures:


Related Product Guide:
Boiler Structure

Using a complete scientific top quality management program, great high-quality and fantastic religion, we win great track record and occupied this area for OEM Supply Water Tube Boilers - Single Drum Steam Boiler – Double Rings , The product will supply to all over the world, such as: Kazakhstan, Berlin, Kenya, We hope we can establish long-term cooperation with all of the customers. And hope we can improve competitiveness and achieve the win-win situation together with the customers. We sincerely welcome the customers from all over the world to contact us for anything you need!
This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
5 Stars By Antonio from Slovak Republic - 2018.11.11 19:52
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
5 Stars By Adam from Paraguay - 2018.06.28 19:27
Write your message here and send it to us

Related products

  • Newly Arrival Hot Water Tube - Boiler Installation Material – Double Rings

    Newly Arrival Hot Water Tube - Boiler Installa...

    Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...

  • Boiler Accessories Supplier - Coke Boiler – Double Rings

    Boiler Accessories Supplier - Coke Boiler R...

    Instruction DZH Coking coal Boiler adopts high efficient heat transfer components – threaded pipe, with a reasonable flue flow rate, boiler efficiency is higher than the national professional standards 6~8%; the convex tube plate and threaded pipe make the boiler drum from quasi-rigid body to quasi-elastic body, which be with airfoil style flue completely avoid the drawbacks of traditional fire tube boiler high temperature tube plate cracking. The boiler dust inertia separation combined...

  • Wholesale Steam Heat Boiler - Boiler Tube – Double Rings

    Wholesale Steam Heat Boiler - Boiler Tube R...

    More Photos Boiler Steel Pipe/Tube is a kind of seamless steel pipe. The manufacturing method is the same as seamless steel pipes, but there are strict requirements for the steel grades used to manufacture boiler steel pipes. According to the temperature level, it is divided into two types: low pressure boiler tube and high pressure boiler tube.

  • 18 Years Factory Industrial Electric Boiler - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

    18 Years Factory Industrial Electric Boiler - ...

    Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

  • China wholesale Steam Boiler - Oil Steam Boiler – Double Rings

    China wholesale Steam Boiler - Oil Steam Boile...

    Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

  • Waste Heat Recovery Boiler Suppliers - Boiler Installation Material – Double Rings

    Waste Heat Recovery Boiler Suppliers - Boiler ...

    Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...