Sticking to the principle of "Super High-quality, Satisfactory service" ,We are striving to generally be a very good business partner of you for installation material, boiler gas flue, boiler accessory installation material, Welcome throughout the world buyers to speak to us for organization and long-term cooperation. We're going to be your reliable partner and supplier.
OEM/ODM Factory Natural Gas Steam Boiler - Boiler Sample Cooling Collection – Double Rings Detail:

Used in Boiler

Sampling Cooler 
This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project.
An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant.
The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils;
It can effectively improve the accuracy of water quality analysis, and at the same time the connecting point between the equipment is simple.
 
Structure
Connected with flange cover the top of the cooling water tank is equipped with coil pipe mouth of the flange cover with holes, in the middle of the cooling coil set in cooling water in the box, the outlet and inlet end of the cooling coil respectively through Kong Yanshen to cooling water tank, among them, the entry of the cooling coil and connected to the boiler, the export of cooling coil, directly above the bus slot of the water in the cooling coil by cooling coil exports into confluence worse, bus slot connected at the bottom of the drain;
The bottom of the cooling water tank is provided with a water inlet, the outlet of the water inlet pipe is connected with the water inlet of the cooling water tank;
The top of the cooling water tank is also provided with an outlet, and the inlet of the outlet pipe is connected with the outlet of the cooling water tank .
 
Principle
Sampling cooler used for boiler room or soda assay sample cooling power station, the water in the boiler and heating system mostly higher temperature, and high temperature is not convenient to sampling, also not easy to determine, in the sample should be cool, so let’s introduce the sample of sampling point sampling cooler for cooling, general requirements to ensure traffic in the 500-700 ml/min, the sample can take a 30 to 40 degrees cold, satisfy the People’s Republic of China power industry DL/T 457-91 standard.
 
Characteristics 
The sampling cooler is suitable for sampling medium such as liquid and gas with high temperature. It has the advantages of compact structure, high heat transfer efficiency, convenient cleaning and long service life.
 
Specifications
1: The sampler tube is stainless steel and the housing is carbon steel.
2. Generally, the sampling cooling pipe can be welded and flange with diameter of 10, 12, 14, 16 and 18mm (or optionally specified by the user). The cooling water interface is DN25 with external thread.
3: The general types are qYl-159/0.32, QYl-219/0.40 and QYl-273/0.54.
4: Whether to combine (that is, whether to support, water tank, valve, etc..
 
Sampling procedure
1.Boiler water sampling
The boiler water sample is generally taken out of the continuous drain pipe of the drum and sent to the cooler.
The sampling point should be as close as possible to the outlet of the drain line drain drum and as far as possible before the first drain valve behind the drain drum.2.Sampling of feed water
The sampling point of the water supply is generally set after the feed pump, and a small pipe should be connected to the vertical pipe line of the water supply pipe on the high-pressure feed pipe before the economizer, from which the sample of the water supply is led to the sampling cooler.
The sampling tube of the feed water should be located at a place where the feed water can be mixed after dosing.
3.Sampling of condensed water
The condensate water sampling point is generally located in the condensate water pipe at the outlet of the condensate pump, should not be installed in the condensate pump entrance, because the pressure of the condensate pump entrance is lower than atmospheric pressure.
4.Hydrophobic sampling
The drainage is generally sampled in the drainage tank.
The sampling point is usually located about 300mm away from the bottom of the drain tank.
Steam samples are condensed into water through the sampling cooler.
The steam flow rate in the steam sampler is generally 20-30kg/h.
The requirements for the sample lead – out duct and cooler are the same as for water sampling.by metal corrosion products in the tubes during sampling.
 
Attention
Stainless steel tubes shall be used for sampling. Carbon steel tubes or brass tubes shall not be used to avoid contamination of the samples by metal corrosion products in the tubes during sampling.
sampling


Product detail pictures:

OEM/ODM Factory Natural Gas Steam Boiler - Boiler Sample Cooling Collection – Double Rings detail pictures

OEM/ODM Factory Natural Gas Steam Boiler - Boiler Sample Cooling Collection – Double Rings detail pictures


Related Product Guide:
Boiler Structure

We're going to commit ourselves to giving our esteemed buyers using the most enthusiastically considerate solutions for OEM/ODM Factory Natural Gas Steam Boiler - Boiler Sample Cooling Collection – Double Rings , The product will supply to all over the world, such as: Estonia, Puerto Rico, Suriname, Customer satisfaction is our goal. We are looking forward to cooperating with you and providing our best services to suit your needs. We warmly welcome you to contact us and make sure you feel free to contact us. Browse our online showroom to see what we can do for you. And then E-mail us your specs or inquiries today.
  • The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Erin from United Kingdom - 2017.10.13 10:47
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Sharon from Philadelphia - 2018.06.26 19:27
    Write your message here and send it to us

    Related products

    • Hot-selling Industrial Electric Boiler - Boiler Water Treatment – Double Rings

      Hot-selling Industrial Electric Boiler - Boile...

      More photos 1. Quartz sand filter — mainly used for the removal of sediment from water. 2. Active Carbon filter– mainly used for chlorine removal and other organic gases and to clear up the taste of water . 3. Water Softener– exchange “ions” of calcium and magnesium with the most common and easiest method. 4. Precision filter– mainly used for removing microorganisms,chlorine,part of the heavy metal ions more precisely 5. High pressure pump– Provi...

    • Trending Products Boiler System - Double Drum Hot Water Boiler – Double Rings

      Trending Products Boiler System - Double Drum ...

      Parameter : SZL Bearing Pressure Hot water Boiler Main Technology Parameter List ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 115/130 115/130 115/130 Feed Water Temp. ℃ 70 70 70 Fuel Consumption  Kg/H ~580 ~900 ~1130 Thermal Efficiency  % 78 80 80 Heating Surface Boil...

    • OEM Customized Diesel Hot Water Boiler - DHL Corner Tube Bulk Water Pipe Boiler – Double Rings

      OEM Customized Diesel Hot Water Boiler - DHL C...

      Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

    • China Best Oil Fired Boilers - Bearing  – Double Rings

      China Best Oil Fired Boilers - Bearing –...

      ·Four Point Contact Slewing Bearings ·Double Row Angular Contact Slewing Bearings ·Crossed Roller Slewing Bearings ·Triple Row Cylindrical Roller Slewing Bearings ·External-toothed Six Row Cylindrical Roller Slewing Bearings

    • New Delivery for Outdoor Coal Boiler - Boiler Water Treatment – Double Rings

      New Delivery for Outdoor Coal Boiler - Boiler ...

      More photos 1. Quartz sand filter — mainly used for the removal of sediment from water. 2. Active Carbon filter– mainly used for chlorine removal and other organic gases and to clear up the taste of water . 3. Water Softener– exchange “ions” of calcium and magnesium with the most common and easiest method. 4. Precision filter– mainly used for removing microorganisms,chlorine,part of the heavy metal ions more precisely 5. High pressure pump– Provi...

    • OEM Customized China Gas Boiler - SZS Gas Oil PLG Boiler – Double Rings

      OEM Customized China Gas Boiler - SZS Gas Oil ...

      Introduction : SZS series boiler body is longitudinal 2-drum, D-type chamber combustion strueture. The furnace is on right side and the convection bank tube is on left side. The body is fixed on the body chassis by flexible supports in the middle and two ends of the lower drum,can secure to let the whole boiler body to expand sideways. Surround furnace there are narrow space membrane cooling tube wall. It is totally sealed and separated between the membrane wall on furnace left side and the c...