Outdoor Coal Boiler Factories - Single Drum Steam Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

We support our buyers with ideal high quality products and high level service. Becoming the specialist manufacturer in this sector, we have gained rich practical experience in producing and managing for industrial thermal oil boiler, boiler meter, industrial gas boiler, Please feel absolutely free to speak to us for organization. nd we believe we will share the best trading practical experience with all our merchants.
Outdoor Coal Boiler Factories - Single Drum Steam Boiler – Double Rings Detail:

Introduction :

Single Drum Chain Grate Coal fired boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover.
The hopper of fuel drops to grate bar, then enter furnace for burning, by the ashes room above the back arch, the flame gets through the first backhaul fire tube to front smokebox, then turn back from front smokebox to the second flue for economizer and dust collector, at last, released into the atmosphere by the draft fan through chimney.

dzl dzg Steam Boiler Equipment Layout

Feature:

1. High thermal efficiency
2. By mechanize operation, reduce intensity of labour of stoker.
3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast.
4. Easy for installation and moving, save a great amount of capital outlay.
5. Fule: Biomass, coal, wood, rice husk, shells, pellets, bagasse, waste , lower calorific value: 12792KJ/Kg.

xiangqingpic

Parameter :

DZG(L)Horizontal Type Coal-Burning Steam Boiler

Main Technology Parameter List

Model  DZG1-0.7-A II
DZG1-1.0-A II
DZG1-1.25-A II
DZG2-1.0-A II
DZG2-1.25-A II
DZG2-1.57-AII
DZG4-1.25-A II
DZG4-1.57-A II 
DZL1-0.7-A II
DZL1-1.0- A II
DZL1-1.25- A II
DZL1-1.57- A II
DZL1-2.45- A II
Rated Capacity T/h 1 2 4 1
Rated Working Pressure Mpa 0.7/1.0/1.25 1.0/1.25/1.57 1.25/1.57 0.7/1.0/1.25/1.57/2.45
Rated Steam Temp. 170/183/194 183/194/204 194/204 170/183/194/204/226
Feed Water Temp. 20 20 20 20
Fuel Consumption  Kg/H 170 330 600 170
Thermal Efficiency  % 77 77 78 78
Heating Surface m² Boiler Body 32.4 33.85 75.75 32.4
Economizer 12.51 24.64 38.5 12.51
Grate area   m² 1.37 2.3 2.05
Designed Fuel  Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max. Transport Weight  T 10.6 19.6 26.5 13.3
Max. Transport Dimension  m 4.75×2.1×2.6 5.7×3.4×4.6 5.49×2.6×3.5 5.65×2.1×2.6
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right225° T4-72-11;3.2A;Righ 315° T4-72-11;4A; Right 315° T4-72-11;3.2A; Right 225°
Motor Power N=1.5 Kw N=3 Kw N=5.5 Kw N=1.5 Kw
Draft Fan Model YX9-35-11;5C ; Right 0° Y-9-26;6.3C ; Right 0° Y-9-26;9D;Right 0° YX 9-35-11;5C; Right 0°
Motor Power N=5.5 Kw N=11 Kw N=22 Kw N=5.5 Kw
Gear Box Model GL-5P
Motor Power N=0.55 Kw
Feed Water Pump Model 1.5WCT-120 1½ GC5x7 1½ GC5x7 1.5WCT-120
Motor Power N=2.2 Kw N=7.5 Kw N=7.5 Kw N=2.2 Kw
Dust Remover Model XD-1 XD-2 XD-4 XD-1

 

Model DZL2-1.0-AII
DZL2-1.25-AII
DZL2-1.57-AII
DZL2-2.45-AII   
DZL4-1.25-AII
DZL4-1.57-AII
DZL4-2.45-AII 
DZL6-1.25-AII
DZL6-1.57-AII
DZL6-2.45-AII 
DZL8-1.57-AII DZL10-1.25-AII
DZL10-1.57-AII
DZL10-2.45-AII
Rated Capacity T/h 2 4 6 8 10
Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.57 1.25/1.57/2.45
Rated Steam Temp. 183/194/204/226 194/204/226 194/204/226 203.04 194/204/226
Feed Water Temp. 20 20 20/60 20 20/60
Fuel Consumption  Kg/H ~310 ~590 ~900 ~1200 ~1440
Thermal Efficiency  % 78 80 77.44 78 80.6
Heating Surface m² Boiler Body 33.85 75.75 142 205 347
Economizer 24.64 38.5 87.2 139.52
Grate area   m² 3.5 4.66 7.4 8.4 10.98
Designed Fuel Type Bituminous Coal Bituminous Coal Bituminous Coal Bituminous Coal
Max.Transport Weight  Ton 21 26.5 38 33 28/29
Max. Transport Dimension  m 5.9×2.2×3.3 6.5×2.6×3.524 7.4×3.2×4.2 8.1×3.2×4.2 7.6×3.2×3.5
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11;3.2A;Right315° T4-72-11;4A;Righ 315° T4-72-11;5A; Right 225° GG8-Na;7.1A; Right 225° 10TG811DRight 225°
Motor Power N=3 Kw N=5.5 Kw N=11 Kw N=11 Kw N=15 Kw
Draft Fan Model Y9-26;6.3C; Right 0° Y-9-26;9D; Right 0° Y-8-39;9D;Right 0° GY8-1;Na9.5D;Right 0° 10JY;9.5D; Right 0°
Motor Power N=11 Kw N=22 Kw N=30Kw N=37Kw N=45 Kw
Gear Box Model GL-5P GL-5P GL-10P GL-16P
Motor Power N=0.55 Kw N=0.55 Kw N=1.1 Kw N=1.1 Kw
Feed Water Pump Model 1½ GC 5×7 1½ GC 5×7 DG 6-25×7 2GC-5xT 1½ GC 6×6
Motor Power N=7.5 Kw N=7.5 Kw N=7.5 Kw N=22 Kw N=2.2 Kw
Dust Remover Model XD-2 XD-4 XD-6 XD-8 XD-10

Product detail pictures:


Related Product Guide:
Boiler Structure

The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for Outdoor Coal Boiler Factories - Single Drum Steam Boiler – Double Rings , The product will supply to all over the world, such as: Belgium, Germany, Costa rica, Facing fierce global market competition, we have launched the brand building strategy and updated the spirit of "human-oriented and faithful service", with an aim to gain global recognition and sustainable development.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
5 Stars By Prima from Grenada - 2018.06.21 17:11
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
5 Stars By Ruth from Danish - 2017.03.07 13:42
Write your message here and send it to us

Related products

  • Manufacturer of Coal Fired Steam Boiler - SHF Coal Water Slury Steam Boiler – Double Rings

    Manufacturer of Coal Fired Steam Boiler - SHF ...

    Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

  • 2019 High quality Outdoor Wood Burners - SZS Fulverized Coal Steam Boiler Hot water boiler – Double Rings

    2019 High quality Outdoor Wood Burners - SZS F...

    Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

  • China Steam Boiler Supplier - Coal Boiler Biomass Boiler Slag Remover – Double Rings

    China Steam Boiler Supplier - Coal Boiler Biom...

    Slag Remover used in Coal Boiler Introduction The Slag Remover is a kind of boiler slag tapping equipment. The carbon slag produced after the coal is burned in the boiler is pushed to the slag storage pit by the grate, and is dragged out of the furnace by the slag machine to clear the slag accumulation.  Technology The high-temperature slag discharged from the furnace is first crushed into small pieces by a pair-roller slag breaker, which is convenient for cooling and transportation; th...

  • OEM Customized China Gas Boiler - Boiler Water Tank – Double Rings

    OEM Customized China Gas Boiler - Boiler Water...

    Used in Boiler Tank accessories (1) Water inlet pipe: The water inlet pipe of the water tank is generally connected from the side wall, but it can also be connected from the bottom or top. When the water tank USES the pipe network pressure to fill the water, the inlet pipe outlet should be equipped with a floating ball valve or hydraulic valve. Generally, there are not less than 2 floating ball valves. The diameter of the ball float valve is the same as that of the inlet pipe, and each ...

  • Manufacturer of Hot Water Tube - Boiler Flue – Double Rings

    Manufacturer of Hot Water Tube - Boiler Flue &...

    Used in Boiler Introduction Industrial smoke exhaust, air into the pipe, the pipe is equipped with a damper (valve) to regulate the wind speed and pressure in the pipe. It is composed of furnace wall, partial heating surface pipe and cladding wall pipe to guide the flow of smoke, and through each heating surface for heat exchange, divided into horizontal flue and tail flue. The main smoke duct section size of the large capacity boiler is very large, in order to bear and transfer the loa...

  • China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings

    China Factory for Boiler Operating - Boiler Sa...

    Used in Boiler Sampling Cooler  This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project. An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant. The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils; It can effectively improve the accuracy of water quality analysis, and at the same time ...